Laserfiche WebLink
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> ;a° 3 B's Truck and Auto Plaza AFacl sr 14749 Thornton Rd Lodi CA 95241 I'ns eG4on Mar 23, 2011 <br /> VIOLATIONS <br /> # VR Code Section HSC=CA Health and Safety Cade CFR=Code d Federal Regulations:V=Violalior RV= epeevidaeOn <br /> V <br /> Specific uiremen is of HSC 25270.4.5(a)are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 49 CFR 112.8(0)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 112.7 a 2 <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 112.7a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge,or provide uivalence as allowed b CFR 112.7(a)(2) <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when pipings not in <br /> service or in standby service for an extended time,or provide uivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction or rovide a uivalence as allowed by CFR 112.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7 a 2 <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 999 Other- I See attached"Continuation-Official Inspection Report'for violation(s)not listed above. <br /> On site to conduct a routine Aboveground Storage Tank (AST) inspection. <br /> 2 & 31. In Table 3 of page 19 of the facility Spill Prevention Control and Counter Measures (SPCC) Plan, <br /> AST's 1- 3 and 4 - 7 are to be inspected monthly and drums are to be inspected weekly. Page 15 and 19 <br /> of the facility SPCC Plan refer to the use of the AST monthly inspection checklist and portable container <br /> checklist in Appendix C. Records on site specify that only ASTs 1-3 (diesel & gas ASTs) are being <br /> inspected monthly. Documentation for inspections of the ASTs 4 - 7 (oil & used oil ASTs) and drums are <br /> not on site nor available for review. Per Health and Safety Code (HSC) 25270.4.5 Each owner or operator <br /> specified in this subdivision shall conduct periodic inspections of the storage tank to assure compliance <br /> with Section 112. Per Code of Federal Regulations (CFR) 112.7(e) Conduct inspections and tests <br /> required by this part in accordance with written procedures that you or the certifying engineer develop for <br /> the facility. You must keep these written procedures and a record of the inspections and tests, signed by <br /> the appropriate supervisor or inspector, with the SPCC Plan for a period of three years. Correct <br /> immediately by ensuring that the required inspections are conducted and documented. <br /> 18. Page iii of the SPCC Plan lists facility site map as Figure 2. Figure 2 is not on site nor available for <br /> review. Figure 3 only shows location of the three fuel ASTs but does not show the other ASTs nor <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTIOV AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> iaspaayr Paecervad er: rue: <br /> l/✓aittQJ �' (209)46868 3453 �i Mffl� (`� <br /> EHD 28-02 Rev 2/19/10 Page 3 APSA INSPECTION REPORT <br />