My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1640
>
2800 - Aboveground Petroleum Storage Program
>
PR0541223
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 9:05:12 PM
Creation date
8/24/2018 7:42:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0541223
PE
2832
FACILITY_ID
FA0014999
FACILITY_NAME
Global Materials Management, LLC
STREET_NUMBER
1640
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1640 N Broadway Ave
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS\B\BROADWAY\1640\PR0541223\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/14/2018 3:41:59 PM
QuestysRecordID
3915887
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Y <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Aboveg ound Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Global Materials Management, L IC 1640 N Broadway Ave, Stockton August 30, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 715 CFR 112.8(c)(8)(v) Failed t regularly test liquid level sensing devices to ensure proper operation. <br /> Liquid level sensing device have not been tested. Procedures and frequency of testing for these devices were not <br /> addressed in the Spill Prev ntion, Control, and Countermeasure (SPCC) plan. Liquid level sensing devices must be <br /> installed in accordance wit CFR 112.8 and shall be regularly tested to ensure proper operation. Immediately <br /> conduct all necessary testi g of liquid level sensing devices, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 717 CFR 112.8(c)(10) Failed to romptly correct visible discharges and/or remove accumulations of oil in diked areas. <br /> Several drums were observed with holes in the sides, leaking oil onto the ground in the yard. Visible discharges <br /> which result in a loss of oil rom a container, including but not limited to seams, gaskets, piping, pumps, valves, rivets, <br /> and bolts, must be promptl corrected. Immediately fix leaks or move all oil to non-leaking containers, clean all <br /> stained areas and contami ated soil, and manage according to the California Code of Regulations Title 22 hazardous <br /> waste regulations. <br /> This is a Class II violation. <br /> 718 CFR 112.8(c)(11) Failed torovide sufficient secondary containment capacity for mobile or portable containers. <br /> The oil storage drums were observed with insufficient secondary containment. No secondary containment was <br /> observed for the 180+ drums of used oil located on the dirt in the yard. Portable oil storage containers must be <br /> positioned or located to pre ent a discharge and shall be furnished with a secondary means of containment sufficient <br /> to contain the capacity of th largest single container with sufficient freeboard to contain precipitation. Immediately <br /> provide sufficient seconds containment for this and all other portable containers at this facility, or provide <br /> equivalence as allowed by FR 112.7(a)(2). <br /> This is a Class II violation. <br /> 719 CFR 112.8(c)(11) Failed to I cate mobile or portable containers to prevent discharge. <br /> The drums of used oil were of located to prevent a discharge. No secondary containment was observed for the <br /> 180+ drums of used oil, whi h were placed on the dirt in the yard. Portable oil storage containers must be positioned <br /> or located to prevent a disch rge and shall be furnished with a secondary means of containment sufficient to contain <br /> the capacity of the largest si gle container with sufficient freeboard to contain precipitation. Immediately relocate <br /> these and all other portable ontainers at this facility to prevent a discharge. <br /> This is a Class II violation. <br /> 726 CFR 112.8(d)(5) Failed to ad quately warn vehicles entering facility to protect piping and other transfer operations. <br /> No warnings were observed P site to warn vehicles of aboveground piping, containers, or other appurtenances. A <br /> warning must be provided to all vehicles entering the facility to be sure that no vehicle will endanger aboveground <br /> piping or other oil transfer op rations. Immediately provide a warning in accordance with CFR Part 112 for all <br /> vehicles entering the facility, r provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.