My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1640
>
2800 - Aboveground Petroleum Storage Program
>
PR0541223
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 9:05:12 PM
Creation date
8/24/2018 7:42:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0541223
PE
2832
FACILITY_ID
FA0014999
FACILITY_NAME
Global Materials Management, LLC
STREET_NUMBER
1640
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1640 N Broadway Ave
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS\B\BROADWAY\1640\PR0541223\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/14/2018 3:41:59 PM
QuestysRecordID
3915887
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Te/ep one: (209) 468-3420 Fax: (209) 468-3433 Web:www.sugov.org/ehd <br /> Aboveg1round Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: 1,r- <br /> SUMMARY <br /> ate: <br /> Global Materials Management, L C 1640 N Broadway Ave, Stockton ugust 30, 2016 <br /> OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 620 CFR 112.7(f)(2) Failed to' <br /> signate a person accountable for discharge prevention. <br /> This facility does not have designated person for discharge prevention. The Spill Prevention, Control, and <br /> Countermeasure (SPCC) Olan shall designate a person at the facility who is accountable for discharge prevention <br /> and who reports to faciity anagement. Immediately designate a person to be accountable for discharge prevention <br /> and update the SPCC Pila to include this information. <br /> This is a Class II violation. <br /> 622 CFR 112.7(f)(3) Failure to onduct spill prevention briefing for oil-handling personnel. <br /> Discharge prevention briefi gs are not conducted. Discharge prevention briefings for oil handling personnel must be <br /> scheduled and conducted t least once a year to assure adequate understanding of the SPCC Plan for that facility. <br /> Such briefings must highlig t and describe known discharges or failures, malfunctioning components, and any <br /> recently developed precaut onary measures. Immediately schedule and conduct a discharge prevention briefing, <br /> and ensure that they are sc ieduled and conducted at least once a year. <br /> This is a minor violation. <br /> 706 CFR 112.8(c)(2) Failed to p ovide and maintain adequate secondary containment. <br /> The oil storage drums and ompactor were observed with insufficient secondary containment. No secondary <br /> containment was observed or the 180+ drums of used oil or the used oil storage in the filter compactor. All bulk <br /> storage tanks must be provi ed with a secondary means of containment for the entire capacity of the tank and <br /> sufficient freeboard to conta n precipitation. Immediately provide sufficient secondary containment for this and all <br /> other tanks at this facility. <br /> This is a Class II violation. <br /> 712 CFR 112.8(c)(6) Failed to to t or inspect each container for integrity based on industry standards. <br /> Integrity testing was not con ucted on the aboveground oil storage containers on site. Each aboveground container <br /> shall be tested and inspecte for integrity on a regular schedule and whenever repairs are made. The qualifications <br /> of personnel performing test and inspections, frequency and type of testing and inspections that take into account <br /> container size, configuration and design shall be determined in accordance with industry standards. Examples of <br /> these integrity tests include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, <br /> ultrasonic testing, acoustic missions testing, or other systems of non-destructive testing. Comparison records and <br /> other records of inspections nd tests must be maintained on site. Immediately conduct the necessary testing and <br /> submit a copy of the test res Its to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Page 5 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.