Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Te/ep one: (209) 468-3420 Fax: (209) 468-3433 Web:www.sugov.org/ehd <br /> Aboveg1round Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: 1,r- <br /> SUMMARY <br /> ate: <br /> Global Materials Management, L C 1640 N Broadway Ave, Stockton ugust 30, 2016 <br /> OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 620 CFR 112.7(f)(2) Failed to' <br /> signate a person accountable for discharge prevention. <br /> This facility does not have designated person for discharge prevention. The Spill Prevention, Control, and <br /> Countermeasure (SPCC) Olan shall designate a person at the facility who is accountable for discharge prevention <br /> and who reports to faciity anagement. Immediately designate a person to be accountable for discharge prevention <br /> and update the SPCC Pila to include this information. <br /> This is a Class II violation. <br /> 622 CFR 112.7(f)(3) Failure to onduct spill prevention briefing for oil-handling personnel. <br /> Discharge prevention briefi gs are not conducted. Discharge prevention briefings for oil handling personnel must be <br /> scheduled and conducted t least once a year to assure adequate understanding of the SPCC Plan for that facility. <br /> Such briefings must highlig t and describe known discharges or failures, malfunctioning components, and any <br /> recently developed precaut onary measures. Immediately schedule and conduct a discharge prevention briefing, <br /> and ensure that they are sc ieduled and conducted at least once a year. <br /> This is a minor violation. <br /> 706 CFR 112.8(c)(2) Failed to p ovide and maintain adequate secondary containment. <br /> The oil storage drums and ompactor were observed with insufficient secondary containment. No secondary <br /> containment was observed or the 180+ drums of used oil or the used oil storage in the filter compactor. All bulk <br /> storage tanks must be provi ed with a secondary means of containment for the entire capacity of the tank and <br /> sufficient freeboard to conta n precipitation. Immediately provide sufficient secondary containment for this and all <br /> other tanks at this facility. <br /> This is a Class II violation. <br /> 712 CFR 112.8(c)(6) Failed to to t or inspect each container for integrity based on industry standards. <br /> Integrity testing was not con ucted on the aboveground oil storage containers on site. Each aboveground container <br /> shall be tested and inspecte for integrity on a regular schedule and whenever repairs are made. The qualifications <br /> of personnel performing test and inspections, frequency and type of testing and inspections that take into account <br /> container size, configuration and design shall be determined in accordance with industry standards. Examples of <br /> these integrity tests include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, <br /> ultrasonic testing, acoustic missions testing, or other systems of non-destructive testing. Comparison records and <br /> other records of inspections nd tests must be maintained on site. Immediately conduct the necessary testing and <br /> submit a copy of the test res Its to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Page 5 of 7 <br />