Laserfiche WebLink
y NED <br /> GEC 0 4 2015 San Joaquin County <br /> Environmental Health Department <br /> ENVIRONMENTAL 1868 East Hazelton Avenue, Stockton, California 95205-6232 0 <br /> coAFiTMW1 <br /> HEA.'"A ' Phone:(209)468-3420 Fax:(209)468-3433 Web:v✓wwsjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Lawrence Livermore National Lab-Site 300 1 15999 W CORRAL HOLLOW RD Tracy September 30 2015 <br /> General Requirements for SPCC Plans <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years u V o R u COS <br /> 614 CFR 112.7(f)(1) Failed to train personnel on discharge prevention u V o R ❑COS <br /> 615 CFR 112.7(0(2) Failed to designate a person accountable for discharge prevention ■V o R o COS <br /> 616 CFR 112.7(f)(3) Failed to schedule and conduct discharge prevention briefings at least annually o V o R in COS <br /> 617 CFR 112.7(8) Plan failed to address security of site and valves,lock out/tag out,and lighting ■V ❑R ❑COS <br /> 618 CFR 112.7(h)(1) Loading/unloading rack containment system not property sized u V o R o COS <br /> 619 CFR 112.7(h)(2) Failed to provide vehicular departure system loading and unloading racks o V o R a COS <br /> 620 CFR 112.7(h)(3) Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles a V a R ❑COS <br /> 621 CFR 112.7(i) Failed to evaluate field constructed container for brittle fracture and take appropriate action o V ❑R ❑COS <br /> 622 CFR 112.70) Failed to include discussion of conformance to discharge prevention and containment procedures n V ❑R o COS <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 701 CFR 112.8(b)(2) Failed to use manual open-and-closed design valves for the drainage of diked areas o V ❑R a COS <br /> 702 CFR 112.8(b)(3), Failed to design facility drainage system from undiked areas to retain in the facility o V o R ❑COS <br /> 112.8(b)(4) <br /> 703 CFR 112.8(b)(5) Failed to provide two lift pumps for more than one continuous treatment unit o V o R a COS <br /> 704 CFR 112.8(c)(2) Diked area is not sufficiently Impervious to contain discharged oil a V a R o COS <br /> 705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions in V ❑R ❑COS <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment o V o R ❑COS <br /> 707 CFR 112.8(c)(3)(1) Failed to keep containment bypass valves closed when not draining rainwater o V o R o COS <br /> 708 CFR 112.8(c)(3)(ii) Failed to Inspect retained rainwater prior to discharge o V ❑R ❑COS <br /> 709 CFR 112.8(c)(3)(iii) Failed to open and close bypass valve to drain rainwater under responsible supervision o V o R o COS <br /> 710 CFR 112.8(c)(3)(iv) Failed to maintain records of drainage from diked areas o V o R ❑COS <br /> 711 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks o V ❑R o COS <br /> 712 CFR 112.8(c)(6) Failed to perform tank inspections that take Into account size,configuration,and design o V o R u COS <br /> 713 CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel ■V o R ❑COS <br /> 714 CFR 112.8(c)(6) Failed to test and inspect containers by appropriately qualified personnel after material repairs o V o R o COS <br /> 715 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils a V ❑R o COS <br /> 716 CFR 112.8(c)(8)(1-iv) Failed to provide each container with a high level monitoring device in V o R a COS <br /> 717 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation ■V ❑R o COS <br /> 718 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge ❑V o R a COS <br /> 719 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas o V a R ❑COS <br /> 720 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers a V ❑R ❑COS <br /> 721 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge o V o R o COS <br /> 722 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V o R ❑COS <br /> Received by Inspector: Phone: Date: <br /> (initial): cute y STACY RIVERA, Senior REHS 6._ (209)468-3440 09/30/2015 <br /> `,' Page 2 of 6 <br />