Laserfiche WebLink
r n n <br />MAR Q 2018 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web, www.s gov.orD/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />CHEVRON STATION #307709' <br />Facility Address: <br />10858 TRINITY PKWY, STOCKTON <br />Data: <br />March 20, 2018 <br />On Site Records <br />203 <br />CCR 2712(b) <br />Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST <br />c V <br />u R <br />❑ COS <br />204 <br />CCR 2712(i) <br />Current monitonng plan approved by the EHD not found on site <br />c V <br />c R <br />n COS <br />205 <br />CCR 2712(i), 2634(e) <br />Failure to submit a current UST Response Plan and have it available onsite <br />o V <br />c R <br />o COS <br />206 <br />CCR 2712 <br />Failure to comply with UST operating permit conditions <br />o V <br />o R <br />o COS <br />207 <br />HSC 25294 <br />Felled to record unauthorized release from primary containment <br />❑ V <br />o R <br />❑ COS <br />206 <br />CCR 2650(e), 2652 <br />Failed to notify the EHD of a reportable unauthorized release <br />c V <br />o R <br />❑ COS <br />209 <br />CCR 2715(c) <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />e V <br />u R <br />u COS <br />210 <br />CCR 2715(e) <br />Designated operator monthly Inspection reports not maintained on site for at least 12 months <br />in V <br />o R <br />o COS <br />211 <br />CCR 2715(f)(2) <br />Designated operator employee training not performed or log not kept <br />c V <br />u R <br />u COS <br />212 <br />CCR 2715(1)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />e V <br />u R <br />❑ COS <br />213 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least dally or log not kept <br />e V <br />o R <br />o COS <br />214 <br />HSC 25281.5(b)(3) <br />Urbuned emergency generator fuel piping not visually Inspected at least monthly or log kept <br />c V <br />o R <br />n COS <br />215 <br />CCR 2712(1) <br />Failure to retain a copy of the permit to operate at the facility <br />u V <br />o R <br />o COS <br />UST System Observations <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />u V <br />u R <br />u COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary Into secondary containment (pre -Jul 2003) <br />o V <br />o R <br />u COS <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />o V <br />o R <br />o COS <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entryinto secondary containment (after Jul 2004) <br />• V <br />u R <br />■ COS <br />305 <br />HSC 25290.1(a) <br />VPH monitoring of the interstitial spaces of the UST system Is not maintained <br />■ V <br />is R <br />is COS <br />306 <br />CCR 2630(d) <br />Monitoring equipment Is not Installed or maintained to detect a leak at the earliest opportunity <br />e V <br />e R <br />u COS <br />307 <br />CCR 2631(g), 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />c V <br />u R <br />u COS <br />306 <br />CCR 2636(f) <br />Failed to maintain a cont nuous monitoring system that activates an audible and visual alarm <br />o V <br />o R <br />n COS <br />309 <br />CCR 2638(Q(1) <br />Monitoring In sump i UDC failed to activate an audible and visual alarm or stop the Bow product <br />o V <br />u R <br />u COS <br />310 <br />CCR 2836(0(5) <br />Failure to meat monitoring requirements in lieu of annual line 5ghtness lest <br />u V <br />n R <br />o COS <br />311 <br />CCR 2636(a), 26410) <br />Failed to properly program or operate leak detection equipment <br />o V <br />o R <br />e COS <br />312 <br />CCR 2638(0, 2641(i) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />o V <br />o R <br />o COS <br />313 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failure to construct, operate, and maintain primary containment as product -light <br />e V <br />o R <br />e COS <br />314 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to have secondary containment or secondary containment not tight <br />e V <br />e R <br />o COS <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />o V <br />o R <br />u COS <br />316 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />o V <br />o R <br />❑ COS <br />317 <br />CCR 2638(0(2) <br />Line leak detector not installed <br />o V <br />o R <br />o COS <br />316 <br />CCR 2636(0(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />is V <br />■ R <br />■ COS <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />u V <br />o R <br />o COS <br />EHD 23-01 Rev. 0922116 <br />FAGO17737 PRO526212 50001 03202018 <br />Page 2 of 4 Underground Storage Tank Program OIR <br />