123-01 Rev. 09/22116 <br />FA0017737 PR0526212 50001 03/2612016 <br />Page 3 of 4 Underground Storage Tank Program CIR <br />0G � <br />MAR 2 0 <br />San Joaquin County <br />Z01e Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.orglehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />CHEVRON STATION 4307709' <br />Facility Address: <br />10858 TRINITY PKWY, STOCKTON <br />Date: <br />March 20, 2018 <br />UST System Observations <br />32D <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />c V c R o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V o R o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />in V o R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V o R a COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red lag <br />n V n R o COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />a V o R u COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />o V o R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />a V a R a COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />a V a R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />o V a R a COS <br />330 <br />CCR 2836(1)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />u V a R o COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />o V o R o COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V o R c COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />a V o R o COS <br />402 <br />CCR 2543(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V a R o COS <br />403 <br />CCR 2643(d) <br />Tnennial 0.1 gph line test for conventional suction piping not performed (pre -January 1964) <br />a V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />a V o R u COS <br />Other Violations <br />2010 <br />Seo below <br />Unlisted General violation <br />o V o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 4 CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />304 <br />HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004). <br />The S1 87 product STP sensor, S2 87 vent fill sensor and 64 91 product STP sensor failed to get a high liquid alarm <br />when tested. The technician on site cleaned out debris from the S1 and S2 sensor and replaced the high liquid float <br />for the S4 sensor "like for like." The continuous monitoring system shall be maintained to detect the entry of the <br />liquid or vapor phase of the hazardous substance stored in the primary containment into the secondary containment <br />and to detect water intrusion into the secondary containment. The sensors were retested during the inspection. All <br />passed. <br />This was corrected on site. <br />This is a minor violation. <br />123-01 Rev. 09/22116 <br />FA0017737 PR0526212 50001 03/2612016 <br />Page 3 of 4 Underground Storage Tank Program CIR <br />