Laserfiche WebLink
Maximize protection <br />vacuum <br />monitored secondary containment <br />system. <br />A Secondary Containment Vacuum <br />Sensing System for use with Veeder- <br />Root's ATG Systems. The Secondary <br />Containment Vacuum Sensing (SCVS) <br />System is designed to detect leaks in double - <br />walled tanks and piping systems while <br />helping to contain a release of product while <br />under vacuum. The system consists of: <br />Vacuum Sensors, connected to tank, <br />sump or piping interstices <br />A Submersible Turbine Pump (STP), <br />to provide a source of vacuum <br />A Smart Sensor Interface with Embedded <br />Pressure Module in a TLS -350 <br />Monitoring System <br />The Vacuum Sensor is interfaced to Veeder- <br />Root's TLS -350 Monitoring System via <br />intrinsically safe wiring to provide system <br />status, replenish rate, alarm, and diagnostic <br />information. <br />Vacuum Sensor Kits are available in a variety <br />of models: <br />• For monitoring double -walled piping <br />and sump interstices <br />• For monitoring double -walled steel tank <br />interstices (see back page) <br />• For double -walled fiberglass tanks <br />These kits differ in the number of vacuum <br />sensors and the configuration of associated <br />liquid sensors. An inline kit mounted liquid <br />sensor is used for Vacuum Sensors <br />monitoring piping and sumps. An external <br />liquid sensor (to be installed in the secondary <br />space at the bottom of the tank) is provided <br />with one of the Vacuum Sensors in the steel <br />and fiberglass tank kits to monitor the tank. <br />VEEDER-ROOT <br />Features and Benefits <br />Satisfy Requirements <br />• Certified to meet California's requitement for <br />secondary space monitoring for tanks and lines <br />as requited by AB 2481 <br />• Satisfies the requirements for Class 1 Leak <br />Detection as defined by the European <br />Standard EN 13160-2 <br />• 3rd Pavy; National Work Group and LG113 <br />listed <br />Reduce Exposure to Risk <br />• Alarms when vacuum cannot be maintained <br />or when replenish rate exceeds 85 liters per hour <br />• The system alarms when liquid is detected in <br />the secondary space <br />Operating Temperature Rating: <br />-25 degrees C to +70 degrees C <br />Cable Length: <br />Sensor Dimensions: <br />5" high x 5" wide 2" deep <br />Facilitates periodic operability testing <br />Leverage Existing Veeder-Root Systems <br />• Uses STP as the vacuum source and works with <br />Red Jacket and FE STDs <br />• Installs in the STP sump and corrects to the <br />console via intrinsically safe wiring <br />• Able to share wiring conduit with other <br />Veeder-Root intrinsically safe (IS) probes and <br />sensors including sump or line leak sensors <br />• Interfaces to the Smart Sensor Interface with <br />Embedded Pressure Module <br />• Provides for positive shut down of pressurized <br />lines when required <br />• Simple irutallation, no need to mess with brine <br />Console Capability <br />The Vacuum Sensor is compatible with <br />the following consoles: <br />Console <br />TLS-350R/EMC w/BIR' <br />TLS -350 Plus/EMC Enhanced` <br />TLS -351 <br />res <br />thcons Ie ade Note: <br />vemor 2 soft�aSaw �re (mor greater) <br />along with an ECPU2 or ECPU w/ NVIVEM 1 board. <br />Standard Models <br />Veeder-Root P/N Description <br />Accessories Part Description Quantity/Length Part Number <br />1/4" NPT Barbed Fittings 3 330020-487 <br />1/4" NPT Barbed Fittings 15 330020-488 <br />Barbed Tee 1 576008-657 <br />Vacuum Hose 25' 25' 332310-001 <br />Vacuum Hose 50' 50' 332310-002 <br />Vacuum Hose 100' 100' 332310-003 <br />3—Way Ball Valve _ 1 576008-649 <br />Schrader Valve Barbed Fitting 3 330020-496 <br />Schrader Valve Barbed Fitting 15 330020-497 <br />kits include mounting bracket, 6' of vacuum hose, relief valve assembly td required) and the appropriate number of liquid sensors, <br />3 -way ball valves, barbed fittings and hose clamps so that each vacuum sensor can monitor a single tank sump or piping interstices. <br />The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module, 8 channel Smart <br />Senior Modules (phi 329356-004) can be used for Vacuum Sensors eight and above. <br />For more information call: 1-888-561-7942 <br />