Laserfiche WebLink
D 8:Solvone <br />IN -TANK ALARMS <br />ALL:LEAK ALARM <br />ALL:HIGH WATER ALARM <br />ALL:OVERFILL ALARM <br />ALL:LOW PRODUCT ALARM <br />ALL:SUDDEN LOSS ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:INVALID FUEL LEVEL <br />ALL:PROBE OUT <br />ALL:HIGH WATER WARNING <br />ALL:DELIVERY NEEDED <br />ALL:MAX PRODUCT ALARM <br />ALL:GROSS TEST FAIL <br />ALL:PERIODIC TEST FAIL <br />ALL:ANNUAL TEST FAIL <br />ALL:NO C:SLD IDLE TIME <br />ALL:GROSS FAIL LINE TNK <br />LIQUID SENSOR ALI-IS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />! ALL:HIGH LIQUID ALARM <br />iALL:LOW LIQUID ALARM <br />ALL:LIQUID WARNING <br />COMM SIDE DIM ALM <br />ALL:DISABLED DIM ALARM <br />ALL:COMMUNICATION ALARM <br />SM'IARTSENSOR ALARMS <br />ALL:COMMUNICATION ALARM <br />ALL:SENSOR FAULT ALARM <br />ALL:FUEL WARNING <br />ALL:FUEL ALARM <br />ALL:WATER WARNING <br />ALL:WATER ALARM <br />ALL:HIGH LIQUID WARNING <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID WARNING <br />ALL:LOW LIQUID ALARM <br />ALL:INSTALL ALARM <br />ALL:SENSOR FAULT WARN <br />ALL:VACUUM WARNING <br />ALL:NO VACUUM ALARM <br />ISG SITE ALARMS <br />ISD STAGE I WARN <br />ISA GROSS FRES WARN <br />ISD GROSS FRES FAIL <br />ISD DEGRD PRES WARN <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK WARN <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES WARN <br />ISD VP PRES FAIL <br />ISD VP STATUS WARN <br />ISD VP STATUS FAIL <br />MISSING RELAY SETUP <br />MISSING HOSE SETUP <br />MISSING TANK SETUP <br />i MISS VAPOR FLOW MTR <br />MISS VAPOR PRES SEN <br />MISSING VP INPUT <br />ISD SETUP WARN <br />ISD SETUP FAIL <br />ISD SENSOR OUT WARN <br />ISD SENSOR OUT FAIL <br />PC -ISD FAILURE <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT WARN <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT WARN <br />ALL:FLOW COLLECT FAIL <br />ALL:AIRFLOW MTR SETUP <br />VAPOR FLW MTR ALMS <br />ALL:CHK VAPOR FLOW MTR <br />PMC ALARMS <br />VP RUNTIME FAULT <br />VP EMISSIONS WARN <br />VP EMISSIONS FAIL <br />VP PRESSURE WARN <br />VP PRESSURE FAIL <br />VP DUTY CYCLE WARN <br />VP DUTY CYCLE FAIL <br />PMC SETUP FAIL <br />IN -TANK. SETUP <br />I T 1 -UNLEADED <br />PRODUCT CODE 1 <br />THERMAL COEFF :.000700 <br />TANK DIAMETER 118.00 <br />TANK PROFILE 4 PTS <br />FULL VOL 19703 <br />88.5 INCH VOL 16085 <br />59.0 INCH VOL 9988 <br />29.5 INCH VOL 3848 <br />FLOAT SIZE: 3.0 IN. <br />WATER WARNING 1.5 <br />HIGH WATER LIMIT: 2.0 <br />iMAX OR LABEL VOL: 19703 <br />OVERFILL LIMIT 90% <br />17732 <br />HIGH PRODUCT 95% <br />18718 <br />DELIVERY LIMIT 150/4 <br />2955 <br />LOW PRODUCT 500 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 01/9 <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />T 2 : PREM I UNI <br />PRODUCT CODE 2 <br />THERMAL COEFF :.000700 <br />TANK DIAMETER 118.00 <br />TANK PROFILE 4 PTS <br />FULL VOL 11849 <br />88.5 INCH VOL 9730 <br />59.0 INCH VOL 6008 <br />29.5 INCH VOL 2257 <br />FLOAT SIZE: 3.0 IN. <br />WATER WARNING 1.5 <br />HIGH WATER LIMIT: 2.0 <br />MAX OR LABEL VOL: 11849 <br />OVERFILL LIMIT 901% <br />HIGH PRODUCT 10664 <br />• <br />95% <br />DELIVERY LIMIT 1125 156 <br />1777 <br />LOW PRODUCT 280 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />