Laserfiche WebLink
T,3:DIESEL <br />PRODUCT CODE3 <br />I PRESSURE LINE LEAS: SETUP <br />THERMAL COEFF :.000450 <br />TANK. DIAMETER 118.00 <br />— — — — — — — — <br />L 2:UNLEHDED FILL BRINE <br />TANK PROFILE 4 PTS <br />TRI—STATE (SINGLE FLOAT) <br />FULL VOL 7817 <br />G !:UNLEADED <br />CATEGORY : PIPING SUMP <br />88.5 INCH VOL'6291 <br />59.0 INCH VOL 3919 <br />TYF:2.Oi3.O11V FIBERGLASS <br />1. 3:UNL FILL SUMP <br />29.5 INCH VOL 1544 <br />2,OIN DIA LEN: 'IBE FEET <br />TRI—STATE (SINGLE FLOAT) <br />3.0IN DIA LEN: 0 FEET <br />CATEGORY : OTHER SENSORS <br />FLOAT SIZE: 3.0 IN. <br />0.20 GPH TEST: REPETITIV <br />WATER WARNING 1.5 <br />HIGH WATER LIMIT: <br />0.10 GPH TEST: AUTO <br />; SHUTDOWN RATE: 3.0 GPH <br />L 4:UNL STP SUMP <br />2.0 <br />I LOW PRESSURE SHUTOFF:NOCATEGORYSTP <br />TRI—STATE (SINGLE FLOAT) <br />MAX OR LABEL VOL: 7817 <br />LOW PRESSURE 0 PSI <br />SUMP <br />OVERFILL LIMIT 90%s <br />7035 <br />HIGH PRODUCT 95% <br />T !:UNLEADED <br />DISPENSE MODE: <br />i L 5:UNL STP BRINE <br />STANDARD <br />TRI—STATE (SINGLE FLOAT) <br />7426 <br />DELIVERY LIMIT 152 <br />SENSOR: HIGH PRESSURE <br />CATEGORY : OTHER SENSORS <br />• 1172 <br />PRESSURE OFFSET: O.OPSI <br />LOW PRODUCT 200 <br />L 6:SPLIT ANNULARS <br />LEAK ALARM LIMIT: 99 <br />Q 2:PREMIUM <br />DUAL POINT HYDROSTATIC <br />SUDDEN LOSS LIMIT: 99 <br />CATEGORY : ANNULAR SPACE <br />TANK TILT 0.00 <br />TYP:2.0/3.01N FIBERGLASS <br />PROBE OFFSET 0.00 <br />2.OIIV DIA LEN: 248 FEET <br />3.01N DIA LEN: 0 FEET <br />L 7:91 STP SUMP <br />SIPHON MANIFOLDED TANKS <br />TRI—STATE (SINGLE FLOAT) <br />TO: NONE <br />0.20 GPH TEST: REPETITIV <br />CATEGORY : OTHER SENSORS <br />LINE MANIFOLDED TANKS <br />0.10 GPH TEST: AUTO <br />TO: NONE <br />I I SHUTDOWN RATE: 3.0 GPH <br />LOW PRESSURE SHUTOFF:NO <br />j <br />LOW PRESSURE U PSI <br />L 8:91 STP BRINE <br />j LEAK MIN PERIODIC: 01% <br />TRI—STATE (SINGLE FLOAT) <br />0 <br />T 2:PREMIUM <br />CATEGORY : OTHER SENSORS <br />DISPENSE MODE: <br />LEAK MIN ANNUAL 0% <br />I STANDARD <br />0 <br />SENSOR: HIGH PRESSURE <br />PRESSURE OFFSET: O.OPSI <br />L 9:91 FILL SUMP <br />PERIODIC TEST TYPE <br />Q 3:DIESEL <br />i CATEGORYE:(SINGLE PIPING SUMPT) <br />STANDARD <br />ANNUAL TEST FAIL <br />TYP:2.0/3.01N FIBERGLASS <br />253 FEET <br />L10:91 FILL BRINE <br />ALARM DISABLED <br />2.OIN DIA LEN: <br />TRI—STATE (SINGLE FLOAT) <br />PERIODIC TEST FAIL <br />3.OIN DIA LEN: 0 FEET <br />CATEGORY : OTHER SENSORS <br />ALARM DISABLED <br />0.20 GPH TEST: REPETITIV <br />GROSS TEST FAIL <br />I <br />0'.10 GPH TEST: AUTO <br />SHUTDOWN RATE: 3.0 GPH <br />L11:DSL STP SUMP <br />ALARM DISABLED <br />LOW PRESSURE SHUTOFF:NO <br />TRI—STATE (SINGLE FLOAT) <br />ANN TEST AVERAGING: OFF <br />LOW PRESSURE 0 PSI <br />CATEGORY STP SUMP <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />T 3:DIESEL <br />UISMOUE: <br />L12:DSL STP BRINE <br />TRI—STATE (SINGLE FLOAT) <br />TNK TST SIPHON BREAKOFF <br />STANDARD <br />S <br />SENSSOR:OR: AVVEE VENTED <br />CATEGORY : OTHER SENSORS <br />PRESSURE OFFSET: O.OPS1 <br />DELIVER`! DELAY 3 MIN <br />j PUMP THRESHOLD 10.00: <br />LINE LEAK LOCKOUT SETUP <br />� <br />L13:DSL FILL SUMP <br />_ — — <br />LOCKOUT SCHEDULE <br />TRI—STATE (SINGLE FLOAT) <br />DAILY <br />CATEGORY : PIPING SUMP <br />LEAK TEST METHOD <br />I START TIME: DISABLED <br />STOP TIME : DISABLED <br />_ <br />L14:DSL FILL BRINE <br />_ — _ <br />TEST ON DATE ALL TANK <br />TRI—STATE (SINGLE FLOAT) <br />JAN 16. <br />_._._, _ <br />CATEGORY : OTHER SENSORS <br />START TIME : 7:55 AM <br />LIQUID SENSOR SETUP <br />TEST RATE :0.20 GAL/HR <br />DURATION 2 HOURS <br />L !:UNLEADED ANNULAR <br />L15:VENT SUMP <br />TST EARLY STOF:DISABLED <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />