COMPLIANCE INFO_2010 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2010 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 1:15:12 PM
Creation date
9/5/2018 3:57:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2010 - 2011
FileName_PostFix
2010 - 2011
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
243
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL <br />TEST DATE: 04/29/11 <br />CLIENT:CHEVRON PRODUCTS <br />TANK INFORMATION AND <br />i TankmAVy <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />AUSTIN, TEXAS 78759 (512) 451-6334 <br />TEST RESULTS <br />WORK ORDER NUMBER2280901 <br />SITE:CHEVRON 307709 <br />Printed 05/12/2011 07:49 <br />TANK INFORMATION <br />Tank ID: 3 <br />Tank manifolded: NO Bottom to top fill in inches: 118.0 <br />Product: DIESEL <br />Vent manifolded: NO Bottom to grade in inches: <br />Capacity in gallons: 7,817 <br />Vapor recovery manifolded: NO Fill pipe length in inches: <br />Diameter in inches: 118.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 167 <br />Overspill protection: YES Stage I vapor recovery: NONE <br />Material: DW FIBERG <br />Installed: ATG Stage II vapor recovery: NONE <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method:VaCUTeet = <br />LEAK DETECTOR TEST RESULTS Test method: FTA <br />Start (in) <br />End (in) <br />Dipped Water Level: <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Dipped Product Level: <br />Probe Water Level: <br />Make: VEEDERROOT <br />Ingress Detected: Water Bubble Ullage <br />Model: ELECTRONIC <br />S/N: <br />Test time: <br />Open time in sec: <br />Inclinometer reading: <br />Holding psi: 30 <br />psi: <br />VacuTect Test Type: <br />NOT <br />Resiliency NOT <br />VacuTect Probe Entry Point: TESTED <br />Test leak rate ml/m: 189.0 TESTED <br />Pressure Set Point: <br />Metering psi: <br />Tank water level in inches: <br />Calib. leak in gph: 3.00 <br />Water table depth in inches: <br />Results: PASS <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />LINE TEST RESULTS Test type: TLD -1 <br />LINE <br />A B C D <br />Material: <br />DW FIBERG <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />NOT NOT NOT NOT <br />Start time: <br />TESTED TESTED TESTED TESTED <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />PRESSURE <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Impact Valves Operational: YES <br />Printed 05/12/2011 07:49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.