Laserfiche WebLink
MONIT( ING SYSTEM CERTIFIC "ION <br />Fo, ose By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3 Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CHEVRON 307709 <br />Site Address: 10858 TRINITY PKWY <br />Facility Contact Person: MANAGER (N-7462-1-10) <br />Make/Model of Monitoring System:TLS-350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: STOCKTON CA Zip: 95210 <br />Contact Phone No: 952-2213 <br />Date of Testing/Service: 04/29/2011 <br />Work Order Number: 2280901 <br />Tank ID: 87 <br />Tank ID: 91 <br />%< In -Tank Gauging Probe. <br />Model: MAG <br />❑X In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 303 <br />Annular Space or Vault Sensor. <br />Model: 303 <br />X Piping Sump/Trench Sensogs). <br />Model: 208/304 <br />Piping Sump/Trench Sensor(s). <br />Model: 208/304 <br />X Fill Sump Sensor(s). <br />Model: 208/304 <br />Fill Sump Sensor(s). <br />Model: 208/304 <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: V/R <br />X Electronic Line Leak Detector. <br />Model: V/R <br />X Tank Overfill/High-Level Sensor. <br />Model: FLAPPER <br />Tank Overfill/High-Level Sensor. <br />Model: FLAPPER <br />71 Other (specify equipment type and <br />model in Section E on page 2). <br />X Other (specify equipment type and model in Section E on page 2). <br />Tank ID: DSL <br />Tank ID: <br />71 In -Tank Gauging Probe. <br />Model: MAG <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 303 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208/304 <br />Piping Sump/Trench Sensor(s). <br />Model: <br />X Fill Sump Sensor(s). <br />Model: 208/304 <br />Q Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: V/R <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: FLAPPER <br />Q Tank Overfill/High-Level Sensor. <br />Model: <br />-111 Other (specify equipment type and <br />model in Section E on page 2). <br />❑ Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: 7/8 <br />® Dispenser Containment Sensor(s) <br />Model: 208/304 <br />X Dispenser Containment Sensor(s) <br />Model: 208/304 <br />X❑ Shear Valve(s). <br />X Shear Valves) <br />ElDispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 3/4 <br />Dispenser ID: 9/10 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208/304 <br />X Dispenser Containment Sensor(s). <br />Model: 208/304 <br />RI Shear Valve(s). <br />7 Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 11/12 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208/304X <br />Dispenser Containment Sensor(s). <br />Model: 208/304 <br />Shear Valve(s).X <br />Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />E1 Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply):❑X System set-up X❑ Alarm history report <br />Technician Name (print): TIMOTHY ELEBECK <br />e—s+ <br />Signature: .A^� uz <br />Certification No.: B35252 License. No.: 743160 (Class 'A' General Enginering Contractor License) <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 11000 N. MoPac Expressway, suite 500, Austin, TX 78759 Date of Testing/Servicing: 04/29/2011 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />