Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org!ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />TRANSPORT SERVICES <br />Facility Address: <br />720 S STOCKTON AVE. RIPON <br />FDaatNUCAL ch 04 201E <br />General Requirements for SPCC Plans <br />614 <br />CFR 112.7(f)(1) <br />Failed to train personnel on discharge prevention■ <br />V = R COS <br />615 <br />CFR 112-7(f)(2) <br />Failed to designate a person accountable for discharge even ton <br />o V o R ❑ COS <br />616 <br />CFR 112.7(f)(3) <br />Failed to schedule and conduct discharge prevention briefings at least4nnua q <br />o V a R c COS <br />617 <br />CFR 112.7(g) <br />Plan faded to address security of site and valves, lock out/tag out, and lighting <br />o V o R e COS <br />618 <br />CFR 112.7(h)(1) <br />Loading/unloading rack containment system not properly IRONMENTAL R M' <br />o V o R e COS <br />619 <br />CFR 112.7(h)(2) <br />Failed to provide vehicular departure system loading and unloading{P:AR, T, l IEN <br />o V o R e COS <br />620 <br />CFR 112.7(h)(3) <br />Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles <br />o V o R e COS <br />o V ❑ R in COS <br />621 <br />CFR 112.7(1) <br />Failed to evaluate field constructed container for brittle fracture and take appropriate action <br />622 <br />CFR 112.70) <br />Failed to include discussion of conformance to discharge prevention and containment procedures <br />- V - R c COS <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 <br />CFR 112.8(b)(2) <br />Failed to use manual open -and -closed design valves for the drainage of diked areas <br />o V O R c COS <br />702 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility <br />o V o R in COS <br />703 <br />CFR 112.8(b)(5) <br />Failed to provide two lift pumps for more than one continuous treatment unit <br />o V c R = COS <br />704 <br />CFR 112.8(c)(2) <br />Diked area is not sufficiently impervious to contain discharged oil <br />o V o R _ COS <br />705 <br />CFR 112.8(c)(1)Container <br />not compatible with oil stored and/or storage conditions <br />❑ V ❑ R ❑COS <br />706 <br />CFR 112.8(c)(2) <br />Failed to provide and maintain adequate secondary containment <br />e V o R c COS <br />'07 <br />CFR 112 8(c)(3)(i) <br />Failed to keep containment bypass valves closed when not draining rainwater <br />c V e R ❑ COS <br />708 <br />CFR 112.8(c)(3)(i) <br />Failed to inspect retained rainwater prior to discharge <br />o V o R e COS <br />709 <br />CFR 112 8(c)(3)(iii) <br />Failed to open and close bypass valve to drain rainwater under responsible supervision <br />o V o R o COS <br />710 <br />CFR 112.8(c)(3)(iv) <br />Failed to maintain records of drainage from diked areas <br />o V o R e COS <br />711 <br />CFR 112 8(c)(5) <br />Failed to provide corrosion protection for partally buried tanks <br />o V o R in COS <br />712 <br />CFR 112.8(e)(6) <br />Failed to perform tank inspections that take into account size. configuration, and design <br />in V o R e COS <br />713 <br />CFR 112.8(c)(6) <br />Failed to perform scheduled tank tests and inspections by appropriately qualified personnel <br />in V e R o COS <br />714 <br />CFR 112.8(c)(6) <br />Failed to test and inspect containers by appropriately qualified personnel after material repairs <br />c V o R e COS <br />715 <br />CFR 1128(c)(7) <br />Failed to provide effective leakage control through defective internal heating coils <br />o V o R ❑ COS <br />716 <br />CFR 112.8(c)(8)(i-iv) <br />Failed to provide each container witn a high level monitoring device <br />o V o R ❑ COS <br />717 <br />CFR 112.8(c)(8)(v) <br />Failed to regularly test liquid level sensing devices to ensure proper operation <br />e V o R c COS <br />718 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment frequently enough to detect potential discharge <br />n V o R c COS <br />719 <br />CFR 112.8(c)(10) <br />Failed to p-omptly correct visible discharges and/or remove accumulations of oil in diked areas <br />■ V o R u COS <br />720 <br />CFR 112.8(c)(11) <br />Failed to provide sufficient secondary containment capacity for mobile or portable containers <br />❑ V o R ❑ COS <br />721 <br />CFR 112.8(c)(11) <br />Failed to locate mobile or portable containers to prevent discharge <br />o V o R - COS <br />722 <br />CFR 112.8(d)(1) <br />Failed to take corrective action on buried piping when exposed for any reason <br />o V c R c COS <br />723 <br />CFR 112.8(d)(1) <br />Faded to provide corrosion protection for buried piping <br />o V - R COS <br />724 <br />CFR 112.8(d)(2) <br />Failed to cap/blank-flange connection at transfer point and mark its origin if not in service <br />o V c. R COS <br />Page 2 of 5 <br />