My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1988 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO 1988 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:21:43 PM
Creation date
9/20/2018 11:31:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 1988 - 2006
FileName_PostFix
1988 - 2006
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />IVIRONMENTAL HEALTH DEPARTMENT <br />304 East Weber Avenue, 3rd Floor, Stockton, CA 95202-2708 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj og v.org <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Toys K US <br />Designated Operator: <br />Inspection Date: <br />Facility,, address: �, ^ <br />16 v 2-4-ry I <br />UST # j <br />r Product <br />Facility Contact: Title: Phone: <br />Monitoring Panel: <br />'TV 7 � <br />Piping system:,.,., <br />❑ Pressurized N/ <br />Suction E) Gravity <br />O_�v//erfill prevention: <br />S Mechanical ❑ Audible/visual <br />Inspection type: ` <br />I,f Routine ❑'Monitoring Certification ❑ Installation ❑ Other: <br />Violations: <br />❑ Ml-RDetect ❑ M2-RPrev <br />❑ M-3 Both <br /># <br />Code Section <br />VIOLATION(S) HSC=California Health & Safety Code; CCR=California Code of Regulations <br />V=Violation; RV=Re eat Violation <br />V R <br />V <br />I <br />HSC 25284 <br />Permit tooperate <br />2 <br />CCR 2637 <br />Secondary containment test performed <br />3 <br />CCR 2711 ) & c <br />Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br />4 <br />HSC 25292.2 <br />Certification of financial responsibility and CFO letter <br />CCR 2632 c 2 D <br />Monitoring & response plan is current and filed with the local agency <br />6 <br />CCR 2712 i <br />Monitoring & response plan is onsite <br />7 <br />CCR 2712 b <br />Maintenance & monitoring records <br />Ml <br />8 <br />CCR 2643 d <br />Daily monitoring of suction piping (pre -January, 1, 1984) <br />9 <br />HSC 25292.1 <br />UST system isoperated to prevent unauthorized release <br />10 <br />CCR 2632 (c)(2) <br />UST monitoring system is present <br />Ml <br />11 <br />CCR 2630 d <br />UST system monitoring equipment is properly located to detect a leak <br />Ml <br />12 <br />HSC 25291 <br />UST system monitoring equipment isoperational <br />M2 <br />13 <br />CCR 2636 1 <br />Continuous monitoring system for underground piping & UDC is present <br />Ml <br />14 <br />CCR 2631 a <br />Primary containment is product tight <br />15 <br />HSC 25291 (a)(2) <br />Secondary containment for UST is tight <br />16 <br />1 CCR 2636 (c)(1) <br />All releases in secondary pipingflow to a collection sum <br />17 <br />HSC 25291 <br />Line leak detectors are installed <br />Ml <br />18 <br />CCR 2635 1 <br />Spill container <br />M2 <br />19 <br />CCR 2635 2 <br />Overfill prevention system <br />M2 <br />20 <br />CCR 2636 (a) <br />Conventional suction piping shall have continuous monitoring & 2° containment <br />21 <br />HSC 25291 (e) <br />Water in 2° containment analyzed & properly disposed of <br />22 <br />1 CCR 2650 <br />Recording/reporting of unauthorized releases <br />Ml <br />23 <br />CCR 2715 <br />Designated Operator: (a) Statement from UST owner; (c -e) Monthly inspection; f) Employee training <br />24 <br />CCR 2638 a <br />Annual monitoring certification <br />25 <br />CCR 2638 a) <br />Annual line leak detector test <br />Ml <br />26 <br />HSC 25284.2 <br />Annuals ill containment testing <br />27 <br />CCR 2636 4 <br />Annual line tightness test <br />Ml <br />28 <br />1 CCR 2661 <br />Repair for tank/piping has had tightness test <br />M2 <br />29 <br />CCR 2643 a <br />Biennial tightness test of gravity piping(pre-January 1, 1984 <br />30 <br />CCR 2643 d <br />Triennial line test for conventional suction piping (pre -January 1, 1984) <br />(Mi) <br />31 <br />HSC 25292.5 <br />Double walls stem located within 1000' of public well-ELD <br />32 <br />CCR 2661 <br />Permit to repair UST system <br />33 <br />HSC 25286 a <br />Permit to alter monitoring system <br />34 <br />HSC 25298 <br />Permit totemporarily close UST system <br />c <br />Permit to close UST system <br />a 9 <br />Disablingleak detection devices <br />a <br />Illegal abandonment of UST system <br />KCEIVEDB: <br />PHONE: UIC <br />Septic system: <br />❑ Serves >_20 people/day <br />TITLE: ❑ Receives other than sanitary waste <br />rL/ / Other disposal methods: <br />V'Dry wells/French Drains <br />EHD 23-02-002 <br />
The URL can be used to link to this page
Your browser does not support the video tag.