My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1987
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
INSTALL 1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:59:41 PM
Creation date
9/20/2018 1:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL 1987
FileName_PostFix
1987
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW UNDERGROUND STORAGE TANKS - PLAN ADDITION/CORRECTION SHEET <br />The following checked and/or underlined items are to be addressed on plans: <br />GENERA <br />1. Provide the namme� and address of the facility. <br />`_/"2. Provide the hme, address, and phone numbers of the contractor(s), facility <br />owner(s), and operator(s). <br />L/ 3. Provide four complete sets of plans. (One to be retained by this office). <br />Include specification sheets, equipment brochures, monitoring, and response <br />�plans. <br />4. Provide plans to scale in nonerasable blueprint. <br />CONSTRUCTION STANDARDS <br />1. <br />Location(s) and numbe of tanks. <br />t/ 2. Type of tank(s) to be installed. <br />A. Steel clad with fiberglass reinforced plastic. <br />1. 35,000 to 40,000 volt Holiday Test required before "setting" tank(s) <br />in ground. <br />B. Fiberglass <br />1. Striker plate dimensions and materials. <br />2. Striker plates under all accessible openings. <br />C. Nonclad steel <br />1. Cathodic protection provided (including nuts, bolts, washers, etc.). <br />a. Approved by-a corros-ion-engineer or NACE technician. <br />b. Document stating inspection method and frequency (Minimum semi- <br />annual inspection required). <br />D. Other types of tanks <br />Z <br />1. Construction specification standards for durability. <br />3. Tank Capacity (List specific gallonage). <br />(� e�. Contents to be stored in each tank (Be specific). <br />A. Verification of product compatability with the tank(s), piling,., monitoring <br />device(s), epoxy or silicone glues, etc. <br />1. List testing organization and approval. <br />Provide manufacturers written installation instructions. (Include all piping, <br />monitors, tanks, etc. <br />Note - NFPA 30 Test required before covering tank and systems. NFPA 30 Test <br />is require on BOTH the Primary and Secondary containment systems. <br />Double walled tanks using pressure or vacuum testing to monitor annular <br />space are exempt from testing secondary container. <br />Note - NFPA 329 "Precision Test" required upon completion of installations. <br />One test result copy to be sent directly to this department from the <br />testing company. <br />
The URL can be used to link to this page
Your browser does not support the video tag.