Laserfiche WebLink
Secondary Containment Testing Report Form - Page 2 of 5 <br />D. Testing of Tank Annular Spaces/Vaults <br />® N/A (No tanks have secondary containment) <br />Test Method Developed By: E] Tank Manufacturer; ® Industry Standard; E] PE; E] Other (Specify): <br />Test Method Used: ❑ Pressure; ® vacuum; ❑ Hydrostatic; ❑ Other (Spec): <br />Test Equipment Used: gauge <br />Equipment Resolution: 0.5" HG <br />pipe Run #: Sat #3 Pipe Run #: Sat #1 <br />Tank #: <br />Tank #: <br />Tank #: DSL <br />Tank #: <br />Is Tank Exempt From Testing? <br />❑ Yes; ® No <br />❑ Yes; ❑ No <br />❑ Yes; ❑ No <br />❑ Yes; ❑ No <br />Tank Capacity (gallons): <br />20,000 <br />Diesel <br />Diesel <br />Diesel Diesel <br />Product/Grade Stored in Tank: <br />DSL <br />30 Min. <br />30 Min. 30 Min. <br />Test Start Date/Time: <br />Tank Manufacturer: <br />Unknown <br />1:40 1:40 <br />Initial Reading (Rj): <br />5.1 PSI <br />Tank Model: <br />Unknown <br />Test End Date/Time: <br />10:45 <br />11:37 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test (minutes): <br />30 Min <br />5.1 PSI <br />5.2 PSI <br />5.1 PSI 0.0 PSI <br />Test Start Time: <br />8:10 <br />0.0 PSI <br />0.0 PSI 0.0 PSI <br />Pass/Fail Threshold or Criteria: <br />Initial Reading (RI): <br />10" HG <br />0.0 PSI 0.0 PSI <br />Test Result: <br />® Pass; ❑ Fail <br />Test End Time: <br />10:10 <br />Final Reading (RF): <br />10" HG <br />Change in Reading (RF— Rj): <br />0.0" HG <br />Pass/Fail Threshold or Criteria: <br />0.0" HG <br />Test Result: <br />® Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />Was leak detection sensor <br />properly replaced and verified <br />as functional after testing? <br />® Yes; ❑ No; <br />❑N/A (Not Removed) <br />❑ Yes; ❑ No; <br />E]N/A (Not Removed) <br />❑ Yes; ❑ No; <br />❑ N/A (Not Removed) <br />❑ Yes; ❑ No; <br />E]N/A (Not Removed) <br />E. Testing of Secondary Piping or Containment Trenches ❑ N/A (No piping 20 containment) <br />Test Method Developed By: ❑ Pipe/Trench Manufacturer; ® Industry Standard; ❑ PE; ❑ Other (Spec): <br />Test Method Used: ® Pressure; ❑ vacuum; ❑ Hydrostatic; ❑ Other (Specify): <br />Test Equipment Used: gauge Equipment Resolution: 0.2 PSI <br />pipe Run #: Sat #3 Pipe Run #: Sat #1 <br />Pipe Run #: DSL <br />Sec. to Dis 2/4 <br />Pipe Run #: DSL <br />Sec. to Disp 1/3 <br />Pipe/Trench Manufacturer: <br />Environ <br />Environ <br />Environ Environ <br />Pipe/Trench Model: <br />Enviroflex <br />Enviroflex <br />Enviroflex Enviroflex <br />Product/Grade in Line: <br />Diesel <br />Diesel <br />Diesel Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test (minutes): <br />30 Min. <br />30 Min. <br />30 Min. 30 Min. <br />Test Start Date/Time: <br />9:45 <br />10:37 <br />1:40 1:40 <br />Initial Reading (Rj): <br />5.1 PSI <br />5.2 PSI <br />5.1 PSI 5.0 PSI <br />Test End Date/Time: <br />10:45 <br />11:37 <br />2:40 2:40 <br />Final Reading (RF): <br />5.1 PSI <br />5.2 PSI <br />5.1 PSI 0.0 PSI <br />Change in Reading (RF — Rj): <br />0.0 PSI <br />0.0 PSI <br />0.0 PSI 0.0 PSI <br />Pass/Fail Threshold or Criteria: <br />0.0 PSI <br />0.0 PSI <br />0.0 PSI 0.0 PSI <br />Test Result: <br />® Pass; ❑ Fail <br />® Pass; ❑ Fail <br />® Pass; ❑Fail ❑ Pass; ® Fail <br />UN -054 - 2/5 www.unidocs.org 02/26/02 <br />