COMPLIANCE INFO_2012 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 11:18:53 AM
Creation date
9/24/2018 11:22:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2012 - 2014
FileName_PostFix
2012 - 2014
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary Containment Testing Report Form - Page 3 of 5 <br />F. Testing of Piping Sumps/Turbine Sumps <br />❑ N/A (No piping/turbine sumps) <br />Test Method Developed By: ® Sump Manufacturer; ❑ Industry Standard; ❑ PE; ❑ Other (Spec): <br />Test Method Used: [:1 Pressure; ❑ Vacuum; ® Hydrostatic; ❑ Other (Specify): <br />Test Equipment Used: Incon TS -STS Equipment Resolution: 0.001" <br />7 <br />Sump #: DSL <br />Sump #: <br />Sump #: <br />Sump #: <br />Sump Diameter (inches): <br />42 <br />Sump Depth (inches): <br />36" <br />Sump Material: <br />FRP <br />Height from Tank Top to Top of <br />Highest Pipe Penetration (inches): <br />12" <br />Height from Tank Top to Lowest <br />Electrical Penetration (inches): <br />2011 <br />Portion of Sump Tested: <br />Bottom Half <br />If turbine shuts down when sump <br />sensor detects liquid, specify <br />turbine shutdown response time. <br />® N/A <br />minutes. <br />❑ N/A <br />minutes. <br />❑ N/A <br />minutes. <br />❑ N/A <br />minutes. <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15 minutes. <br />minutes. <br />minutes. <br />15 minutes. <br />Test Start Date/Time: <br />9:24 10:04 <br />Initial Reading (Rt): <br />2.542 2:466 <br />Test End Date/Time: <br />9:39 10:19 <br />Final Reading (RF): <br />2.454 2.465 <br />Change in Reading (RF — Rt): <br />0.002 0.001 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />Test Result: <br />® Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />Was leak detection sensor <br />properly replaced and verified as <br />functional after testing? <br />® Yes; ❑ No; <br />❑ N/A (Not Removed) <br />❑ Yes; ❑ No; <br />❑ N/A (Not Removed) <br />❑ Yes; ❑ No; <br />❑ N/A (Not Removed) <br />❑ Yes; ❑ No; <br />❑ N/A (Not Removed) <br />G. Testing of Under -Dispenser Containment (UDC) <br />❑ N/A (No dispensers or no UDC) <br />Test Method Developed By: ® UDC Manufacturer; ❑ Industry Standard; ❑ PE; ❑ Other (Specify): <br />Test Method Used: ❑ Pressure; ❑ Vacuum; ® Hydrostatic; ❑ Other (Spec): <br />Test Equipment Used: Incon TS -STS I Equipment Resolution: 0.001 <br />UN -054 - 315 www.unidoes.org 02/26/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.