My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2200 - Hazardous Waste Program
>
PR0536804
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 11:43:02 AM
Creation date
9/27/2018 2:22:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0536804
PE
2229
FACILITY_ID
FA0021137
FACILITY_NAME
OILSTOP
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
01
SITE_LOCATION
301 W KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Visual Inspection findings: A visual inspection of the tank and its affiliated <br />pumps, piping and ancillary equipment did not reveal signs of leaks, corrosion, <br />weld cracks or breaks, or scrapes in protective coating which may cause a <br />release from the tank system. A description of all discrepancies noted during the <br />visual inspection is included with this report. Initials: P15 <br />Seismic/Anchoring: <br />Civil engineer wet stamped seismic/dynamic/hydrostatic load calculations <br />provided as Attachment "D" <br />Seismic/Anchoring findings: The tank as designed and operated, and the <br />containment area in which it is located are adequately anchored and are <br />seismically sound. Initials: � V 5 <br />Leak Test: 191(g)(9)/192(k)(10) <br />The waste oil storage tank and ancillary equipment were <br />pneumatically pressure tested during the inspection. The system <br />held a pressure of 1.25 psig for 15 minutes with no pressure drop. <br />Integrity testing findings: Based on the above noted integrity test and the <br />results obtained from that test, the tank has sufficient integrity for its intended <br />use. Initials: ) r!% <br />Tank Drawing: 191 (g)(2)(E)/l 92(k)(2)(E)) <br />Tank and Fittings: See Attachment "A" <br />Ancillary Conveyance Equipment: See Attachment "B" <br />Tank Dimensions : <br />8'-4" wide x 3'-7" deep <br />Tank Height: <br />Overall: 4'-10" <br />Tank Gross Capacity (Volume): 1,000 gallons <br />Oil Stop Lodi 5 Waste Oil Assessment <br />