My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 -2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_1998 -2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 9:38:21 AM
Creation date
9/28/2018 11:22:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_1998 -2011
FileName_PostFix
1998 -2011
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 6 of 7 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sums LN <br />Fill Riser Containment Sumps are Present, but were Not Tested U <br />Test Method Developed By: U Sump Manufacturer U Industry Standard U Professional Engineer <br />U Other (Spec) <br />Test Method Used: U Pressure U Vacuum U Hydrostatic <br />U Other (Spec) <br />Test Equipment Used: <br />Fill Sump # Fill Sump # <br />Equipment Resolution: <br />Fill Sump # Fill Sump # <br />Sump Diameter: <br />Sump Depth: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R,): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Chane in Reading RF -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />U Pass U Fail <br />U Pass U Fall <br />U Pass U Fail <br />U Pass U Fail <br />Is there a sensor in the sump? <br />tlYes U No <br />U Yes U No <br />U Yes U No <br />U Yes U No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />U Yes U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />Was sensor removed,for testing? <br />U Ves U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />Was sensor properly replaced and <br />verified functional after tcsting`r <br />V Yes U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />U Yes U No U NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br />No Secondary Containment on fill risers at this site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.