Laserfiche WebLink
K <br /> '1 r <br /> Specificgtion R91QZ5-01 <br /> ^' 4.12 Pilot test duration would be approximately one week or until four carbon <br /> canisters have been exhausted,whichever occurs first. Approximately one week <br /> would be required to get up the pilot .test system. If carbon is exhausted within <br /> a few days, data would be evaluated. This pilot test Work Plan would be revised <br /> as necessavy, including evaluation of alternative air pollution control technology. <br /> 5.0ir_I xri nW 11 n ' <br /> 5.1 Design of a soil treatment cell, extending from site surface to the water table <br /> approximately seventy feet (70') below grade, would be based on results of the <br /> Pilot Test. Figure B-1 presents a schematic diagram of a typical vapor well which <br /> T would be installed for both extraction and passive air injection. Design of the <br /> well field would be based on the results of the pilot test and evaluation of the <br /> lateral and vertical extent of soil contamination. Construction of the well field <br /> could proceed subsequent to the pilot test and concurrently With the assessment <br /> investigation (i.e. from the soil borings drilled for installation of the wells and <br /> manometer points). <br /> 5.2 Configuration of Vad%g ZQUe Air Wells <br /> Vadose zone air wells would be installed, if necessary, and constructed to <br /> mWmize distances between passive injection and extraction points. Minimization <br /> of air travel distance increases control of airflow rates and vacuums and, <br /> consequently, remediation process control and predictability. <br /> To promote air flow through the treatment cell,air intake and extraction points <br /> wc,uld be stratifed as follows. <br /> Strata 1 15' to 45' <br /> Strata 2 45' to 75' (approximate depth of water table) <br /> 5.3 W H Construction <br /> At each air-well location, two eight-inch diameter boreholes would be drilled <br /> adjacent to one another. It is anticipated that one well would be installed to a <br /> depth of app►oximately 63 feet and the second well to a depth of approximately <br /> 30 feet. For a maximum well depth, the borehole would be advanced from the <br /> soil surface to the lower unit of air release or withdrawal(at about 65 feet below <br /> grade of the water table capillary fringe). Vadose wells would end above the <br /> aquifer free water surface to minimize the yield of free art-1 condensate water <br /> mixed systems. After completion of the borehole to its final depth,the borehole <br /> would be partially backfilled with a natural well packing material (sand, pea <br /> stone, gravel, etc.) to be selected after site soil evaluation. <br /> The lower vertical air conduit would be placed on the backfill v-Ath its upper end <br /> approximaisly two feet above grade(until shortened during air conduits network. <br /> construction). Additional well packing would be added until the packing reaches <br /> B-5 REMEDIATION <br /> SERVICEA. INC. <br /> �b <br />