Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Name: Tracy Municipal Airport Address: 5749 S. Tracy Blvd., Tracy Date: Aug <br /> Aug 16, 2010 <br /> VIOLATIONS <br /> # V R Code Section HSC=CA Health and Safet Code;CFR=Code of Federal Regulations:V=Violation;RV=Repeat violation <br /> V Sped c requirements of HSC 25270.4.5 a are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 X CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 11 2.7 a 2 <br /> 50 X CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 11 2.7 a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 11 2.7 a 2 <br /> 53 X CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 X CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> ROUTINE ABOVEGROUND PETROLEUM STORAGE ACT (APSA) INSPECTION <br /> "Checklist left on site at time of inspection (8/16/10). Inspection report completed on 8/17/10. <br /> Violations: (6, 16, 18, 24, 31, 35, 48, 50, 53, 59) <br /> 6. The Professional Engineer (PE) certification is incomplete. No statements were made regarding <br /> procedures for inspections and testing, the adequacy of the plan, or the preparation in accordance with <br /> the requirements of 40 CFR Part 112. The PE certification must include all of the aspects in 40 CFR Part <br /> 112.3(d)(1). Immediately obtain a complete PE certification for the facility's Spill Prevention Control and <br /> Countermeasure (SPCC) plan. Submit a copy of the completed, certified SPCC plan to the EHD within <br /> 30 days (9/17/10). <br /> 16. The management approval section of the SPCC plan was left blank. The plan must have the full <br /> approval of management at a level of authority to commit the necessary resources to fully implement the <br /> plan. Immediately obtain required management approval for the SPCC plan for this facility. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RAT IS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Phone: Received By: Title: <br /> (209) 468-3440 11 <br /> EHD 2T!!)172/19/10 Page 3 APSA INSPECTION REPORT <br />