Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Williams Tank Lines Facility 1477 Tillie Lewis Dr., Stockton Inspection Jun 28, 2011 <br /> Name: Address- Date: <br /> VIOLATIONS <br /> # V v Code Section HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations;V=Violation;RV=Repeat violation <br /> Specific requirements of HSC 25270.4.5(a)are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 11 2.7 a 2 <br /> 50 X CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as allowed <br /> by CFR 112.7a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 X CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping, and appurtenances,or provide equivalence as <br /> allowed by CFR 11 2.7 a 2 <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations, or provide equivalence as allowed by CFR 112.7(a)(2 <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) INSPECTION <br /> "Inspection conducted on June 28, 2011. Report completed on July 1, 2011. Checklist left on site at <br /> time of inspection. <br /> Violations: (19, 21, 27, 28, 46, 50, 53) <br /> 19, 21 & 27. The inventory listed in the SPCC Plan does not include the old used oil tank, the 100 gallon <br /> diesel tank, the oil totes, or the truck tankers that are stored on site. Discharge & drainage controls and <br /> potential equipment failure are not addressed for any of the unlisted containers. The SPCC Plan must <br /> include the correct type of oil and storage capacity of each fixed storage container, and either the type of <br /> oil and storage capacity of each portable container or an estimate of the potential number of portable <br /> containers, types of oil, and anticipated storage capacities. The Plan must include discharge or drainage <br /> controls, such as secondary containment around all containers and other structures, equipment, and <br /> procedures for the control of a discharge, and a prediction of the direction, rate of flow, and total quantity <br /> of oil which could be discharged as a result of each type of major equipment failure. Immediately update <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RAT .T IS AGILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Phone: Received By. Title. <br /> (209)468-3440 <br /> EHD 28-0 19110 Page 3 APSA INSPECTION REPORT <br />