EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2131
>
2800 - Aboveground Petroleum Storage Program
>
PR0535925
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 11:37:12 AM
Creation date
10/2/2018 11:43:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535925
PE
2833
FACILITY_ID
FA0009893
FACILITY_NAME
NORTHERN CALIF POWER - LODI
STREET_NUMBER
2131
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2131 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01CULIVLLJ <br /> FEE 5 2016 <br /> SPOOITank Inspection 2016 <br /> • NCPA CTI,Lodi,CA 95240 ENVIRONMENTAL. <br /> Tank Inspection Frequency: STI, SP001 inspection determination and inspector requirements. The <br /> tank is a factory built tank with a working volume of 1,886 gallons. The tank is within secondary <br /> containment and it has a continuous release detection monitor. The class of the tank is class 1. Class 1 <br /> tanks of this tank's volume require annual visual external inspection by the owner's inspector who is <br /> familiar with the tank's operation. <br /> STI SP001, External Inspection Check list for this type of tank. <br /> 7.1.3 Inspection Review: Complete <br /> 7.1.4 Name Plate Data: Missing <br /> 7.1.5 Inspect Fabrication vs Standard. Meets the criteria of a UL 142 tank with the exception of the <br /> missing emergency vent. <br /> 7.1.6 Inspect the foundation: The foundation is concrete free of settlement, spalling, with a few small <br /> cracks. The tank is anchored to the foundation in 6 places. Anchoring prevents seismic shifting and <br /> floatation if the dike were flooded. <br /> 7.1.7 Inspect Tank Supports: The tank is supported by a steel collar the same diameter as the tank. <br /> The collar height is 3". The collar is in good condition with no signs of significant corrosion. <br /> 7.1.8 Inspect the CRDM, continuous release detection monitor and secondary containment. The <br /> secondary containment is an earthen diked coated with shotcrete. The shotcrete is cracked and <br /> missing in some areas. The main purpose of the shotcrete is to protect the dike from erosion and pest <br /> burrows. In some places there are sign of erosion and burrows. The eroded earth should be removed <br /> and the burrows filled and concrete be reapplied. Cracks in the concrete should be sealed to prevent <br /> further deterioration. <br /> 7.1.8.1 Inspect the general condition of the tank. The tank is in good condition with no signs of damage <br /> of significant corrosion. <br /> 7.1 8.2 Inspect for foreign materials in secondary containment. The secondary contain contains leaves <br /> and dirt and is covered by moss in several areas. The leaves, dirt and moss shall be removed. <br /> 7.1.9 Ancillary Equipment Inspection. <br /> 7.1.9.1 Piping and Connections. The piping and connections are in good condition. However, there are <br /> areas where dirt has come in contact with the pipes. The dirt must be removed to prevent corrosion <br /> where it contacts the pipes. There are approximately four piping nozzles which are not capped or blind <br /> flanged. Piping nozzles must be capped or blind flanged when not in use. Piping support were <br /> inspected and were good with the absence of corrosion or fretting of the pipe that is in contact with the <br /> support. <br /> 7.1.9.2 Emergency Vent and Normal Vent. The normal vent was inspected and is free of obstructions. <br /> The emergency vent was missing and the tank roof is non-frangible. The tank requires emergency <br /> venting unless approved by the authority having jurisdiction. <br /> John Strandberg PE,rwaterguysarwater uy.com 1-866-388-0404 3 1 P a e <br />
The URL can be used to link to this page
Your browser does not support the video tag.