My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2800 - Aboveground Petroleum Storage Program
>
PR0536558
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2019 4:20:05 PM
Creation date
10/2/2018 11:53:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536558
PE
2832
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECENED <br /> [',.U:, G 2 7.013 <br /> D. Results of Testing/Servicing ENVIRONMENTAL <br /> HEALTH DEPARTMENT <br /> Software Version Installed: <br /> Complete the following checklist: <br /> x Yes No' Is the audible alarm operational? <br /> x Yes No' Is the visual alarm operational? <br /> x Yes U No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> x Yes C No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> P,. <br /> er o ration? <br /> x Yes - No. If alarms are relayed to a remote monitoring station.is all communications equipment(e.g.modem)operational? <br /> N/A <br /> x Yes D No' For pressurized piping systems, does the turbine automatically shut down 9 the piping secondary containment monitoring system <br /> U WA detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all that apply) <br /> EISump/Trench Sensors; ElDispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failureldisconnection? ElYes; E]No. <br /> Yes No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> WA valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? If so,at what percent <br /> of tank capacity does the alarm trigger? % <br /> Yes' x_ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> Yes' K No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)OProduct; ❑Water. V <br /> es,describe causes in Section E,below. <br /> x Yes No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> x Yes No' I Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> SYSTEM COLD START WAS PERFORMED DUE TO H8 COMMS ALARM,ALL(37)SENSORS WERE TESTED FOR PROPER OPERATION. <br /> *212 TRANSITION SUMP *137 TRANSITION SUMP 97 <br /> Monitoring System Certification Page of 12107 <br />