My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2800 - Aboveground Petroleum Storage Program
>
PR0536558
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2019 4:20:05 PM
Creation date
10/2/2018 11:53:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536558
PE
2832
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Pilot Flying J 617 <br /> Facility Name: y 9 Bldg.No.: <br /> site Address: 15100 N. Thornton Road city: Lodi Zip; 95242 <br /> Facility Contact Person: Holly Marlowe Contact Phone No.: 20( 9 ) 339-4066 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 5 /2 / 2 0 1 2 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: Diesel Tank#1 Tank ID: Diesel Tank#2 <br /> In-Tank Gauging Probe. Model: 846390-109 x In-Tank Gauging Probe. Model: 846390-109 <br /> Annular Space or Vault Sensor. Model: 794390-420 x Annular Space or Vault Sensor. Model: 794390-020 <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: LD3000 Fill Sump Sensor(s). Model: <br /> n Mechanical Line Leak Detector. Model: x- Mechanical Line Leak Detector. Model LD3000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 846390-109 x_ Tank Overfill/High-Level Sensor. Model: 846390-109 <br /> Other(specify equipment t e and model in Section E on Page 2). X- Other(specify equipment t e and model in Section E on Page 2). <br /> Tank ID: Diesel Tank#3 Tank ID: <br /> x In-Tank Gauging Probe. Model: 846390-109 _ In-Tank Gauging Probe. Model: <br /> x Annular Space or Vault Sensor. Model: 794390420 Annular Space or Vault Sensor. Model: _ <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> • Tank Overfill/High-Level Sensor. Model: 646390-109 Tank Overfill/High-Level Sensor. Model: <br /> x Others ecif a ui ment ty2e and model in Section E on Pae 2). Other(specify a ui ment type and model in Section E on Pa e 2). <br /> Dispenser ID: 19M Dispenser ID: 19s <br /> x Dispenser Containment Sensor(s). Model: 794390-208 xJ Dispenser Containment Sensor(s). Model: 794390-208 <br /> x Shear Valve(s). ' Shear Valve(s). <br /> Dispenser Containment Floats and Chains. Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 20M Dispenser ID: 20S <br /> x Dispenser Containment Sensor(s). Model: 794390-208 x Dispenser Containment Sensor(s). Model: 794390-208 <br /> x Shear Valve(s). x Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). Dis enser Containment Floats and Chain(s). <br /> Dispenser ID: 21M Dispenser ID: 21S <br /> x Dispenser Containment Sensor(s). Model: 794390-208 x- Dispenser Containment Sensor(s). Model: 794390-208 <br /> x Shear Valve(s). Ici Shear Valve(s). <br /> Dispenser Containment Floats and Chains Dispenser Containment Floats and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers'checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ><System set-up is Alarm history report �y <br /> Technician Name(print): Daniel Visser Signature: /�r <br /> Certification No.: A31963 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 ) 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:5 /2 / 2 0 1 2 <br /> Monitoring System Certification Page of 12107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.