Laserfiche WebLink
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pilot Flying J 617 Bldg.No.: <br /> Site address: 15100 N. Thornton Road city: Lodi Zip: 95242 <br /> Facility Contact Person: Holly Marlowe Contact Phone No.: 20( 9 ) 339-4066 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 5 /2 / 2 0 1 2 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: _ Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> i Other(s2ecify a ui ment type and model in Section E on Pae 2). Other(specify equipment t e and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> r_i In-Tank Gauging Probe. Model: i In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: i Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model Tank Overfill/High-Level Sensor. Model: <br /> 7 Other(specify a ui ment a and model in Section E on Page 2). Other(specify a ui ment type and model in Section <br /> Dispenser to: 22M Dispenser ID: 22S <br /> x-i Dispenser Containment Sensor(s). Model: 794390.208 Dispenser Containment Sensor(s). Model: 794 W209 <br /> K, Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 23M Dispenser ID: 23S <br /> Dispenser Containment Sensor(s). Model: 794390-208 Dispenser Containment Sensor(s). Model: 794390-208 <br /> Ki Shear Valve(s). Shear Valve(s). <br /> 1 Dispenser Containment Floats and Chain(s). Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 24M Dispenser ID: 24S <br /> Dispenser Containment Sensor(s). Model: 794390-208 Dispenser Containment Sensor(s). Model: 794390-208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats and Chains Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): z System set-up x'Alarm history report <br /> Technician Name(print): Daniel Visser Signature: <br /> Certification No.: A31963 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 ) 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:5 /2 / 2 0 1 2 <br /> Monitoring System Certification Page of 12107 <br />