My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:47:10 PM
Creation date
10/4/2018 2:58:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2004-2009
FileName_PostFix
2004-2009
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicins,,,. <br /> Software Version Installed: 12 -1 ' R y <br /> Com lete the following checklist: <br /> is Yes ❑ No* Is the audible alarm operational'' <br /> 19 Yes ❑ No* Is the visual alarm o tional'? <br /> • Yes ❑ No* Were all sensors visuall i ted, functionallytested,and confirmed operational? <br /> ■ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that oilier equipment <br /> will not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> Y N/A operational? <br /> ■ Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping sceondary containment <br /> ❑ N/A I monitoring system detects a leak,fails to operate.or is electrically disconnected? If yos: which sensors initiate <br /> positive shut-dawn? (Cheek all that apply) AD Sumplfrench Sensors, #Dispenser Containment Sensors. <br /> Did ou confirm positive shutdown due to leaks i10 sensor failure/discormection" •Yes; ❑No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 0 N/A mechanical overfill prevention valve is installed). is the overfill warning alarm visible and audible at the tank <br /> fill point(s) and operating properl}'? If so, at what percent of tank capacity does the alarm trigger? <br /> % <br /> ❑ Yes* N No Was any monitoring equipment replaced" If yes, identifc specific sensors. probes or other equipment <br /> re laced and fist the manufacturer name and model for all replacement its in Section E,below. <br /> ❑ Yes* 0 No Was liquid found inside any secondary containment systems designed as dry systems'? lCheok all that apply,) <br /> ❑ Product: ❑Water. If yes, describe causes in Section E,below. <br /> N Yes ❑ No* Was monitorin• stem sct-up reviewed to ensure r settings!Attach setup its,if ap l_icablc_ <br /> It Yes ❑ No* Is all monitoring ui ment operational r manufacturer'sspecifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: . ....... <br /> PaKe 2 of 3 WIN <br />
The URL can be used to link to this page
Your browser does not support the video tag.