COMPLIANCE INFO 2004-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:47:10 PM
Creation date
10/4/2018 2:58:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2004-2009
FileName_PostFix
2004-2009
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 ~ Page of <br /> S. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Contaimnent Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ❑Industry Standard X Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> O Other(Specify) <br /> Test Equipment Used: MTS Mag Probe W/TDU Meter Equipment Resolution: .001" <br /> Fill Sump N 1—91 Fill Sump#2—87 Fill Sump#3—DO <br /> Sump Diameter: 42" 42" 42' <br /> Sum the 39" 38" 43" <br /> Height from Tank Top to Top of 21" 19" 18" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 18" 17' 17" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good <br /> testing: <br /> Portion of Sump Tested 23" 21" 20" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 10 Min 10 Min 10 Min <br /> starting test: <br /> Test Start Time: 13:11 12:53 14:01 <br /> Initial Reading(Rd: 0.000" 0.000" 0.0w <br /> Test End Time: 13:23 13:05 14:13 <br /> Final Reading(RF): 0.000" 0.001" 0.000" <br /> Test Duration: 12 Min 12 Min 12 Min 12 Min <br /> Change in Reading(RF-RO: .000" 001" 000" <br /> Pass/Fail Threshold or Criteria: +/-.002" +/-.002" +/-.002" +/-.002" <br /> Test Resak: X Patin O Fail X Fess O no R Paas ❑Fail O Pass O Fail <br /> Is there a sensor in the sump? X Yes O No X Yes ❑No X Yes O No ❑Yes O No <br /> Does the sensor alarm when <br /> either product or water is X Yes ❑No ❑NA X Yes O No ❑NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? X Yes O No DNA I X Yes O No DNA X Yes O No DNA O Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes O No DNA I X Yes ❑No DNA X Yes ❑No ❑NA ❑Yes ❑No ENA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-rp for jaikd rests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.