My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:54:01 PM
Creation date
10/4/2018 3:59:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2010-2015
FileName_PostFix
2010-2015
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TE'§T RESULTS <br /> JIâ–ºTanlmobgy <br /> TEST DATE: 02/25/11 8501 N EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2279670 <br /> CLIENT: KARAM SINGH AUSTIN,IN,TEXAS 78759(512)451-6334 <br /> SITE: TRACY PETRO <br /> Tank ID: 3 3 Tank manifolded: No Bottom to top fill in inches: 118.0 <br /> Product: DIESEL2 Vent manifolded: NO Bottom to grade in inches: <br /> Capacity in gallons: 7,817 Vapor recovery manifolded: NO Fill pipe length in inches: <br /> Diameter in inches: 118.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 167 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: VAPORLESS <br /> Fluid volume in gallons: Model: LD2000 <br /> Tank water level in inches: S/N: 06101129 <br /> Test time: NOT Open time in sec: 6.00 <br /> Number Of thermisters: TESTED Holding psi: 33 NOT <br /> Specific gravity: Resiliency cc: 130 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 12 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: <br /> Ullage volume: Material: DN FIBERG <br /> Ullage pressure: Diameter(in): <br /> Results: Length (ft): <br /> Test psi: <br /> DATA FOR LITS-4T ONLY: Bleedback cc: <br /> Time of test 1: Test time(min): <br /> Temperature: NOT Start time: NOT NOT NOT NOT <br /> Flow rate(cfh): TESTED End time: TESTED TESTED TESTED TESTED <br /> Time of test 2: Final gph: <br /> Temperature: Result: <br /> Flow rate(cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: FE PETRO <br /> Temperature: <br /> Flow rate (cfh): Impact Valves Operational: UNKNOWN <br /> COMMENTS COMMENTS <br /> Printed 03/11/2011 09:03 MTUTTLE <br />