My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:54:01 PM
Creation date
10/4/2018 3:59:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2010-2015
FileName_PostFix
2010-2015
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> Fr a By All Jurisdictions Within the State of California <br /> Authority Cited.*Chapter 6.7, He>✓and Safety Code;Chapter 16,Division 3 Title 23, Carfnia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be Prepared for each monitoring system control Panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The mnedopemtor must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: TRACY PETRO City: TRACY CA Zip:95376 <br /> Site Address: 3400 N.MACARTHUR DR Contact Phone No: 814-8581 <br /> Date of Testing/Service: 02/25/2011 <br /> Facility Contact Person: KARAM SINGH <br /> Make/Model of Monitoring System:VR-TLS350 PLUS Work Order Number: 2279670 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: T1-PRE Tank ID: T2-REG <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 302 Annular Space or Vault Sensor. Model: 302 <br /> )( Piping Sumprrrench Sensor(s). Model. 208208 <br /> Piping Sumplfrench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model 208 208 <br /> X Mechanical Line Leak Detector. Model: LD2000 NX <br /> Mechanical Line Fill LLea Fill Sump Sensk Detector. Model Model: LD2000 <br /> ea <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> -XI Tank Overfill/High-Level Sensor. Model: EXT.ALARM Tank Overell/High-Level Sensor. Model: EXT.ALAR. <br /> Other(specify equipment type and model in Section E on page 2). Others eci <br /> ( p y equipment type and model in Section E on page 2). <br /> TanklD: Tank ID: <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 302 Annular Space or Vault Sensor. Model <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector, Model: LD2000 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: EXT.ALARM Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment <br /> (s pe ty <br /> type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s) Model:208 <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> ❑Dispenser Containment Floats)and Chalets). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> X❑Dispenser Containment Sensgr(s) Model:208 X Dispenser Containment Sensor(s). Model'208 <br /> X❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, 1 have also attached <br /> a copy of the(Check all that apply): ❑System Set-up X❑Alarm history report <br /> Technician Name(print): KELVIN CRUZ Signature: <br /> Certification No.: A22519 License.NO.: 743160(Class'A'General Engmedng Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 02/25/2011 <br /> Monitoring System Certitication Page 1 of 3 Based on CA form dated 03/08 <br />