My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:54:01 PM
Creation date
10/4/2018 3:59:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2010-2015
FileName_PostFix
2010-2015
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 v4pe 1%/ Page 5. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTING <br /> Test Method Developed By: F-1 UDC Manufacturer El Industry Standard ❑X Professional Engineer <br /> ❑ Other (Specify) <br /> Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br /> ❑ Other (Specify) <br /> Test Equipment Used: VPLT Equipment Resolution: +/-0.0020 <br /> UDC# 1/2 UDC# 3/4 UDC# 5/6 UDC# 7/8 <br /> UDC Manufacturer: unknown unknown unknown unknown <br /> UDC Material: fiberglass fiberglass fiberglass fiberglass <br /> UDC Depth: 2 ' 9" 2 '10" 2 '10" 219-- <br /> Height <br /> ' 9"Height from UDC Top to Top of 13" 13" 12-1 1211 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 6.. 611 6" 8" <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested: t 15" 15.. 15" 14" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both �yes�Na�N �Yes�Na�N �Yes�Na�N Yes[]No x�IV <br /> product and water)?* <br /> Turbine shutdown response time: n/a n/a n/a n/a <br /> Is system programmed for fail-safe ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ <br /> shutdown?* Yes N X Yes N x N Yes N x N Yes No x <br /> Was fail-safe verified to be yes❑No�N Dyes�No x�I�T Dyes <br /> N ElYes ElNoEN <br /> Wait time between applying - <br /> pressure/vacuum/water and starting 5 mins 5 mins 5 mins 5 mins <br /> test: <br /> Test Start Time: E3:3 13:35 13:04 13:06 <br /> Initial Reading(Rt): 0 0 0 <br /> Test End Time: 13 :50 13:19 13 :21 <br /> Final Reading(RF): +0.0001 -0.0013 -0.0008 <br /> Test Duration: 15 mins 15 mins 15 mins <br /> Change in Reading(R F-RI ): -0.0005 +0.0001 -0.0013 -0.0008 <br /> oWas <br /> Fail Threshold or Criteria: +/-0.0020 +/-0.0020 +/-0.0020 +/-0.0020 <br /> sensor removed for testing? Yes N NA x Yes N N x Yes N N x Yes NopNd <br /> Was sensor properly replaced and �N NA x Ye�N NA x <br /> oaA <br /> verified functional after testing? x Ye ❑Ye�N NA x ❑yes❑N <br /> Comments- (include information on repairs made prior to resting, and recommended follow-up forfailed tests) <br /> t If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is'NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.