COMPLIANCE INFO 2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:54:01 PM
Creation date
10/4/2018 3:59:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2010-2015
FileName_PostFix
2010-2015
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VIj` _EIVC[ <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.L TJ C <br /> MONITORING SYSTEM CERTIFICATION MAR 0 4 2015 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Tllle 23,CallfornMOR NMENTA+ <br /> Regulallons <br /> This form must be used to document testing and servicing of monitoring equipment A separate certillution or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a ropy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: TRACY PETRO Bldg.No.: <br /> Site Address: 3400 N.MACARTHUR DR City: TRACY Zip: 95376 <br /> Facility Contact Person: KARAM SINGH Contact Phone No.: 209-814-Ml <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 2/27/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/servictld: <br /> Tank ID: Tl-PREMIUM Tank ID: T2-REGULAR <br /> r In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: mag <br /> r Annular Space or Vault Sensor. Model: 303 r Annular Space or Vault Sensor. Model: 373 <br /> r Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: 208 <br /> V Fill Sump Sensor(s). Model: 208 r Fill Sump Senwr(s). Model: 20B <br /> r Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> r Electronic Line Leak Detector. Model r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: ext alarm r Tank Overfill/High-Level Sensor.Model: ext alarm <br /> Other(specify equipment ify equipment and model in Section E on Pae 2). <br /> Tank ID: T3-Diesel Tank ID: <br /> r In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: 303 r Annular Space or Vault Sensor. Model: <br /> V Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: ext alarm r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2 . Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). r Dispenser Containment Floats and Chain(s). <br /> Dispenser 5/6 Dispenser 718 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Floats and Chain(s). Dispenser Containment Floats and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Senwr(s).Model: r Dispenser Containment Senwr(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Floats and Chain(s). <br /> -if the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that appWJ:r System set- <br /> up r Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: 835255 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (80))800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/27/2015 <br /> Monitoring System Certifrcatlon Page 1 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.