Laserfiche WebLink
' SECOR L.1 <br />e <br />1 <br />1 <br />1 <br />t <br />1* <br />1 <br />1 <br />1 <br />First Quarter 2003, Quarterly Progress Report <br />April 15, 2003 <br />Page 2 <br />3.0 EVALUATION OF GROUNDWATER EXTRACTION AND SOIL VAPOR EXTRACTION <br />SYSTEMS <br />31 Introduction <br />GWE and SVE systems were activated on July 3, 2000 A brief description and performance evaluation <br />of the remedial systems during 1003 are presented below Certified analytical reports and chain -of - <br />custody documentation and remedial system operation and maintenance field data sheets are included in <br />Appendices D and E, respectively <br />3 2 Groundwater Extraction System <br />The GWE system consists of groundwater extraction wells EX -1, EX -2 and EX -3 (Figure 5) These wells <br />are equipped with submersible pumps connected through mechanical piping to a series of granular <br />activated carbon (GAC) vessels prior to an industrial sewer discharge point Chevron discharges treated <br />groundwater at the subject site under City of Lodi wastewater discharge permit #310 <br />To assess effectiveness of the GWE system, process samples were collected bimonthly during this <br />reporting period Sample locations include a Influent port (INFL), prior to the first GAC vessel, between <br />the first and second GAC vessels (MID -1), between the second and third GAC vessels (MID -2), and prior <br />to discharge (EFFL) to the Industrial sewer During these sampling events, INFL, MID -1, MED -2 and EFFL <br />samples were analyzed for TPHg, BTEX, MtBE, TBA, DIPE, EtBE, TAME, ethanol, methanol, EDB and <br />1,2 -DCA Maximum concentrations of detected constituents are presented below Current and historical <br />analytical information is presented as Table 3 <br />Zone <br />Maximum Constituent Concentrations (µg11) <br />October 8 through December 17, 2002 <br />MtBE <br />TBA EtBE <br />TAME <br />Ethanol <br />Methanol <br />INFL <br />40 <br /><10 3 <br /><2 <br /><100 <br /><400 <br />MID -1 <br /><2 <br /><10 <2 <br /><2 <br /><100 <br /><400 <br />MID -2 <br /><2 <br /><10 <2 <br /><2 <br /><100 <br /><400 <br />EFFL <br /><2 <br /><10 <2 <br /><2 <br /><100 <br /><400 <br />ExEx laminations <br />< Indicates the constituent was not present at or above the method reporting limit shown <br />Between December 17, 2002 and March 18, 2003, the GWE system discharged a total of 1,080,272 <br />gallons of treated groundwater over a period of 91 days (Table 4) As of March 18, 2003, the GWE <br />system has treated a total of 6,398,966 gallons Calculated discharge rates during the 1Q03 monitoring <br />period ranged from 6 84 to 10 29 gallons per minute (gpm) <br />During 1003 the system extracted an estimated 0 3 pounds of TPHg and 0 2 pounds of MtBE To date, <br />'the system has extracted approximately 8 7 pounds of TPHg, 0 2 pounds of benzene, and 84 8 pounds of <br />• MtBE Plots of GWE system mass removal trends and influent groundwater TPHg, benzene, and MtBE <br />concentrations versus time are shown on Figure 6 and 7, respectively <br />1 I IChevron1957751Penodic Monitoring\Quartedy Progress Reports120031ist Quarter -2003 QPR1 REV C doc <br />