Laserfiche WebLink
❑Immersion ❑Contact ❑Thru-Transmission ❑Thickness Measure <br />[nspection Method ❑Longitudinal ®Shear -wave (Angle: 45,60,0 deg. } <br />j <br />DC -scan ®A -scan DB -scan _❑Other: <br />Instrument <br />Model Serial No. Cal. Due Date <br />USN60 023N1 -1C 09 -June -12 <br />USK7D JM110367B 23 -Mar -12 <br />Transducer <br />Frequency size i Serial No. <br />5MHZ .5" D790 <br />5MHZ 5" BOORFMK <br />Setup Data <br />FEB 2 5 2G16 <br />Page 46 of 179 <br />Diti7sion: <br />590 <br />3/30/12 Page: I of 1 <br />Address: <br />3985 TEAL CT Gn��_701: Iob Number: <br />B13194/393420 <br />.5" T <br />BENICIA, CA 94510 Purchase Order: <br />257-1-5166 <br />NA Scan Equipment: Manual <br />707-746-5870 Reference Number: <br />53C204 <br />Client: <br />Matrix Services Pan Number: <br />T23 <br />Address: <br />500 West Collins Ave. Code/Specification: <br />ASME Section V <br />Orange Ca.92867 Procedure: <br />CVX-UT-002 REV. 4 <br />Contact: <br />Austin Acceptance Criteria: <br />ASME Section VIII <br />Location: <br />Tracy California Technique: <br />Manual UTSW <br />❑Immersion ❑Contact ❑Thru-Transmission ❑Thickness Measure <br />[nspection Method ❑Longitudinal ®Shear -wave (Angle: 45,60,0 deg. } <br />j <br />DC -scan ®A -scan DB -scan _❑Other: <br />Instrument <br />Model Serial No. Cal. Due Date <br />USN60 023N1 -1C 09 -June -12 <br />USK7D JM110367B 23 -Mar -12 <br />Transducer <br />Frequency size i Serial No. <br />5MHZ .5" D790 <br />5MHZ 5" BOORFMK <br />Setup Data <br />Reflector <br />Location. <br />Amplitude <br />Gate Level <br />.25" T <br />5 divisions <br />8011/o <br />NA Cal. Standard: Chevron ASME Standard <br />.5" T <br />10 divisions <br />42% <br />NA Scan Equipment: Manual <br />.75 T <br />1.25 divisions <br />24% <br />NA Couplant: Ultra Gel II <br />Additional Information: Area was scanned to detect and confirm low previously detected. <br />Test Results Quantity Inspected: I Quantity Accepted: I Quantity Rejected: 0 <br />On March 30"`, 2012 Mistras Group was requested to perform Manual UTSW testing on 100% of the manway <br />to shell weld of T23. The weld was internally inspected with a Odeg. to determine if any laminar defects existed <br />in the heat affected zone. A 45 and 60 deg wedge was used to encompass the entire weld to determine if any <br />reject able weld defects existed per the ASME code. <br />Results: <br />After externally inspecting 100% of the weld it was determined to be of sound material. The weld was found to <br />have no rejectable indications per code and the heat affected zone was free of laminar defects. <br />[]Attached Documentation: <br />Technician, Level & Date: Customer (sign): Management Review (sign): <br />100 -FORM -008 I Rev. 12 <br />