Laserfiche WebLink
Daily Terminal Ya <br />Terminal: <br />Week <br />spection Checklist <br />NOTE: Enter J if OK, X it corrective action is necessary (i.e., repair, replacement, etc), or I If does not apply (i.e., couldn't sump fitters due to no loads). Provide detail or corrective actions taken <br />:r comment section following the checklist If a gauge reading is requested, enter the reading rather than a check mark. <br />Tasks below are oerformed durino each shift unless indicated otherwise <br />MON TUE WED <br />THUR <br />F SAT <br />SUN - ITEM <br />N D N <br />I - <br />Aboveground Piping and Flange Leaks -Visually inspect for drips and leaks, particularly at connection points <br />and flanges. Visually inspec t Flange and blind bolts. Look for signs of damage and/or corrosion. Ensure there are <br />arrows showing flow direction. Ensure piping is clearly marked with product service. (Refer to API 570, section <br />5.12 for Piping Inspection Code; API 1637 for Marking/Labeling) <br />D I N D ND (N D N D - N D <br />. ,. <br />✓ <br />/ <br />l/ <br />/ <br />Cathodic Protection System (where applicable) -Visually inspect to ensure the system is operational, monthly, <br />complete the separate cathodic protection inspection form. <br />Motor Operated Valves (MOVs) Air Leak - Listen for airleaks <br />Piping Supports - Ensure supports are in good condition, sturdy,, inspect forsigns of rust ordamege. <br />✓ <br />✓ <br />✓ <br />_ <br />Automatic Gates -Ensure gates open and close properly and all safety features (sensor loops, contact alarms, <br />lights, sounds) work correctly. Look for obvious signs of damage to gate operator, rollers, chains, hydraulic <br />Pumps <br />Walkthrough Gates -Ensure gates are closed and locked and show no signs of damage or unauthorized entry <br />/� <br />►� <br />- <br />✓ <br />Off-site Drain Valves - Ensure valves are closed and locked when not in use and show no signs of damage <br />✓ <br />f <br />/ <br />Video Cameras - Ensure cameras are present and show no obvious signs of damage. Check monitorinside to <br />ensure they are working properly, are in focus and are adjusted to provide maximum viewing <br />Dike Walls - Inspect walls for damage, points for potential leaks during spill (ex: animal burrows, cracks) <br />Fenceline - Visually inspect the fenceline forholes in fencing, saggingibroken barbed wire, gaps underfencing, <br />vegetation growing into fencing, suspicious packagesrpeopie near fencing, signs of unauthorized entry <br />Valves - Look for product leaks and drips; Ensure valves are in the correct position and locked when not in use; <br />Ensure water draw and roof drain valves are closed and locked when not in use <br />✓ <br />Manifold Area - Ensure there are no signs of leaks; valves that are not in use are closed and locked; product <br />valve labels are correct <br />/ <br />Seals and Locks - Ensure all seals and locks are in place and show no signs of tampering <br />Dock Security Checks - Walk length of dock ispecting above and below; verify all gates are closed and locked <br />at all times, dock buildings kept locked when dock unattended, check for hose leaks, check lighting at night <br />5W <br />Pump Off pumps - Visually inspect for leaks, listen for excessive or unusual noise when running, verify oil in <br />lubricator, check pressure gauges, verify valves locked <br />Leaks - Look for signs of drip or leaks. Pay close attention to welds, seams, valves and nozzles. <br />Tank Information Stenciling - Ensure fire diamond is present, not faded and correct. Ensure stenciling is correct <br />(product, levels of concern, valve identification) <br />Tags/Decals - Update storage tank In-service tagsrdecals (Ex: Last time inspected, Cleaning dates, Capacity, <br />etc.) <br />Floating Suction Level Indicator - Verify floating suction level indicator is moving with product salesfreceipts <br />Tank Shel I - Visually inspect for bulges, dents or signs of corrosion. <br />Raw"�.: <br />Monitoring Well - Visually inspect to ensure well is free of water, product and vapors. <br />Ste. <br />Rags - Ensure there are no ragsfabsorbent pads laying about <br />Electrical Cabinets -Ensure all cabinets are tightened closed and locked <br />r <br />Driver Restroom -Ensure deanfiness, check vandalism <br />. <br />✓ <br />Drips and Spills - Look for evidence of product that could be a sign of a leak and could be a slipping hazard. <br />Take corrective action immediately. <br />V <br />Test Room - Ensure cleanliness, samples appropriately labeled and stored; ensure exhaust fans are <br />operational; lock room as appropriate <br />t/ <br />Trash - Remove all trash and debris; empty trash cans <br />MAY '2'6;'017 <br />Last Updated: 04/11/13 <br />Banta Terminal <br />EN` IRONMENTAL 'HEALTH <br />DEPARTIAEl'ti <br />