Laserfiche WebLink
ty ,X 3/4" CONDUIT FOR PUMP POWER 3/4" CONDUIT TO TLM <br /> RIN <br /> \ MAX. DEPTH 3/4" TYP. FILL TUBE TO ELECT. PANEL - 1 PER TANK - - / <br /> --- 1" CONDUIT TO INTRINSICALLY 54 45 MANHOLE 3/4 EXPLOSION <br /> SAFE GUTTERMONITOR PROOF 45' ELBOW <br /> CONTROL PANEL <br /> (1 PER TANK) PEA GRAVEL 2'•x 1'-0"x V-0" STYROFOAM <br /> -- 2" BLACK IRON NIPPLE <br /> 5' "' S6 2" BALL VALVE (MAKE HANDI,� -- - 2" ELL <br /> MAX. iv ACCESSIBLE FROM GRADE) / -- EXPLOSION PROOF p <br /> CTION <br /> co U� / \ \ \\ 3UNPVC PIPE OPEN AT BOTTOM, Q <br /> < o `a TOP OF FIBERGLASS OVERLAY <br /> FUEL-GUARD <br /> SECTION z a z STEEL PLATE FILTER SEPARATOR 57 <br /> N <br /> a N ar W J DET A \ -1/1 / O PLLD CONTAINMENT SUMP REDUCER. <br /> FIBERGLASS REDUCER ON THE OUTSIDE 70 <br /> c ` 2" BLACK IRON NIPPLE 51 TURBINE PUMP FI ENSURE WATER TIGHTNESS <br /> — 0Z i o 1 7_" NIPPLE <br /> / ig^ On, PLLD 2" BLACK IRON ELL 56 2" BALL VALVE (FULL I <br /> ORT, MAKE HANDLE JUNCTION BOX <br /> I o I ACCCESSIBLE FROM GRADE (EXPLOSION PROOF) <br /> -� O9 CONTAINMENT SUMP ^� i/2•' BALL VALVE (MAKE HANDLE 111 ) I <br /> P TUBE \a - ACCESSIBLE FROM GRADE I <br /> A M Q 15 (FOR HIGH WATER TABLE] \ 1/2" BRAIDED STAINLESS)STEEL <br /> 'UBIN�LDRKI BONN STREET ELL 3/4" CONDUIT TO ELECT. <br /> SEAL OFF <br /> D Il PANEL PUMP POWER <br /> NDUIT TO <br /> TURBINE PUMP f \ ` ' 2"x24 FLEXIBLE CONNECTOR (INTRINSICALLY SAFE <br /> \ _ MALE BY MALE SWIVEL tq GUTTER AT MONITOR <br /> BOTTOM EDGE / 2" N.P.T, COUPLER CONTROL PANEL 3" PVC OR FRP PIPE OPEN AT <br /> OF CROWN 56 2" BALL VALVE (MAKE HANDLE 3/4" CONDUIT TO BOTTOM. <br /> PLAN \ SLOPE ACCESSIBLE FROM GRADE TLM RISER 2" NPT 2" FRP BELL x MALE <br /> 2" SCH. 40 FRP. BELL x MALE THREADED <br /> ADAPTER <br /> 0 0 PENETRATION BOOT— COUPLER THREADED ADAPTOR <br /> 2" BLACK IRON 90' ELL 3"x2" BOOT WITH ROLL BACK BOOT <br /> STEEL PLATE 3"xL BOOT WITH TEST PORT 73 (FOR CONDUIT) TEST PORT 73 AFTER TESTING <br /> 14 2"x24" FLEXIBLE ROLL BACK BOOT AFTER TESTI G PENETRATION BOOT <br /> g DET B COONNECTO EL MALE BY —3" FRPMALE 21 <br /> CONCRETE SLOPE AT TANK MANHOLES PLAN z' FRP zo SWVEL 2'•x24" MxMS FLEXIBLE ` <br /> 1 4"=1'-0" CONNECTOR \ FIBERGLASS All SUMP SECTION AND TANK <br /> / 1/4" BRAIDED STAINLESS STEEL 1/4" BALL VALVE NOTE: DO NOT EXCEED \ COLLAR CONNECTIONS INSIDE AND OUTSIDE <br /> TUBING VENT LINE MANUFACTURERS SPECIFIED TO ENSURE WATER TIGHTNESS <br /> rCl��� FOR DETAIL OF TANK SLAB 1/4" BLACK IRON NIPPLE BEND RADIUS. 2" FRP PRODUCT 20 21 <br /> (a n SEE SHEET F-2 (`-� 54 48" MANHOLE PIPE IN 3" ERR <br /> � o > a„� � +C” - I/4' STREET ELL SECONDARY CONT. <br /> a � �_ .g o�Y a ^W 51 TURBINE PUMP 2'•x 1 0•'x 1'-0" STYROFOAM 4" N.P.T. PIPE O <br /> za " z - PEA GRAVEL v�'•,.`y M <br /> or �, a BACKFILL d _UJ' E LIQUID SENSOR 88 <br /> \� F ( y�rii ° 4" N.P.T. PLUGGED <br /> z IO - - - - - _ _ - = r _ 71- 1 <br /> �� �°g A ELEVATION <br /> NEW TANK DIMENSION 5x „ TURBINE WITHOUT FILTER <br /> 0 0 o I CHART `�" EXPLOSION PROOF - - <br /> TANK TANK ( / JUNCTION BOX N <br /> n ^ SIZE LENGTH 7I CONTAINMENT SUMP REDUCER, <br /> O 4" FILL UDE W POSITIVE SHUT OFF \ 3/4" EXPLOSION <br /> 12,000 GAL 24'-0-1/4" PROOF 45• ELBOW FIBERGLASS REDUCER ON THE OUTSIDE to <br /> II TO ENSURE WATER TIGHTNESS <br /> / AT 05% TANK CAPACITY 45 \ 15,000 GAL. SEAL OFF <br /> I O _ 2" BALL VALVE (MAKE HANDLE <br /> o - y (OU TSIDEOF CALIFORNIA & ARIZONA) 20,000 GAL. 3T-8-3/4" 74 2"x24" FLEXIBLE ACCESSIBLE FROM GRADE) <br /> y 46. 4" FILLBE (CALIFORNIA & ARIZONA) CONNECTOR MALE BY <br /> o / ILI \ "-- 2" BLACK IRON 90° ELL <br /> MALE SWIVEL <br /> MONITOR PROBE TO LOW NOTE: le 3/4" CONDUIT TO I <br /> 0 3 11 <br /> —END OF TANK. 87 VERIFY TANK LENGTH AUTOMATIC TANK <br /> GAUGE I O <br /> WITH MANUFACTURER. JUNCTION BOX <br /> FUEL-GUARD <br /> j I I 1° CONDUIT TO O FILTER SEPARATOR 57 <br /> w I I INTRINSICALLY SAFE <br /> GUTTER AT MONITOR O 1/2" BLACK IRON STREET ELL <br /> I SLOPE TANKII" IN lo, CONTROL PANEL O <br /> \ - DOWN TOWAIDS FILL END `x. (1 PER TANK) 1/2" BRAIDED STAINLESS STEEL TUBING DRAIN LINE <br /> \I 3/4" CONDUIT FOR CONNECTED TO TANK BUNG WITH 1/2" PORT TO 1/2'• <br /> PUMP POWER TO THREAD-OLET ON RISER <br /> 1 ELECT. PANEL <br /> Li T -i PER TANK I FIBERGLASS ALL SUMP SECTION AND TANK COLLAR <br /> CONNECTIONS INSIDE AND OUTSIDE TO ENSURE WATER TIGHTNESS <br /> IL 88 LIQUID SENSOR <br /> °p <br /> T2'- <br /> SEE DET. A ABOVE T —��� �I�_STEEL PLATES UNDER EACH SEE DET. B ABOVE III—III—I I_ FILTER MOUNTING <br /> 0OPENING BY TANK MANIJFACTURER3" PVC OR FRP PIPE OPEN AT ELEVATIONBRACKET FOR 4'• PIPE 59N. SEE TANK DIMENSION CHART MIN. BOTTOM. <br /> C <br /> T UT <br /> WITH <br /> FOR SUPPORRISER TURBINE WITH FILTER <br /> 7 <br /> _ 10' DIA. 15,000 GAL. FIBERGLASS TANK AND EXCAVATION SECTION ( I;UO '3 TURBINE 1 NOT USED <br /> NO SCALE <br /> INSTALLATION INSTRUCTIONS: JUNCTION BOX (EXPLOSION PROOF) <br /> A PULL STRING MAY BE IN THE TANK. INSTALL A <br /> NEW FULL LOOP PULL STRING IF THE STRING IS <br /> MISSING OR BROKEN. THE PULL STRING IS NOT A 4" TOP SEAL ADAPTOR VAPOR RECOVERY ADAPTOR TLM PROBE MOUNTING FITTING 8'0 <br /> TANK MANUFACTURER WARRANTY ITEM, INSTALL FOR SLOPE SEE DET. $9 AND CAP 79 30 AND CAP 31 34 FOR SLOPE SEE DET. p9 FOR SLOPE SEE DET. #9 <br /> 'FHE SENSOR AT 'IHE BOTTOM CENTERLINE OF THE 4" CAP ON RISER TANK PLUG - TORQUE TO <br /> FRP TANK INTERSTITIAL SPACE, CABLE LENGTH FROM 78" SECURED MANHOLE 37 TAN FPL LBS. PRIOR TO — ISOLATION CAP <br /> INTERSTITIAL SENSOR TO TOP OF RISER EOUEALS INSTALLING ISOLATION CAP TANK FITTING <br /> ONE-HALF TANK CIRCUMFERENCE PLUS RISER HEIGHT 4 1 /2" FROM 0 4 1 2 <br /> TOP OF SPILL ROP✓ G.E. SCS 1202 COMPRESSION RING <br /> EXPLOSION PROOF > e °' c a <br /> uNcnoN Box o . 4 BUCKET TO s . e TOP OF °A SILICONE SEALANT <br /> ° n ° n. .d. ° e ° a ° tx ___ -d. 4 ° e <br /> 13•' MANHOLE W/ �.o. .ad TOP OF SLEEVE °b. y ° '�' 4- ° ISOLATION <br /> 3' MIN, 6" MAX BETWEEN LID AND SECURED LIDd d' SPILL °�? <br /> ...d - TANK FITTING BASE <br /> 37 BUCKET BnsE —� I <br /> TOP OF J-BOX AND RISER CAP SPILL BUCKET 39 <br /> WATER TIGHT SPILL BUCKET 38 <br /> MONITOR PLUG 89 TO TOP I <br /> OR <br /> 4"-150# COUPLING <br /> 4•'-150# COUPLING SLEEVE UNUSED FITTING <br /> '-- --- '', <br /> 4 . <br /> 3/4" CONDUIT To TURBINE SUMP LAST STEP, FIBERGLASS ENTIRE ASSEMBLY, IN FIELD <br /> II4" SCH, 40 GALVANIZED RISER JUNCTION BOX <br /> 1" MAXIMUM , <br /> PRIMED AND WRAPPED <br /> 4" SCH. 40 NIPPLE (GALVANIZED) 4" ALUMINUM FILL TUBE <br /> PRIMED AND WRAPPED w/ POSITIVE SHUT OFF <br /> DEVICE: INSTALL AT 95% <br /> 4"-150A SCH 40 COUPLING OF TANK CAPACITY 45 11 11 2 3/4" CONDUIT FROM II 2 TANK FITTING ISOLATION DETAIL <br /> _ (GALVANIZED) PRIMED AND ANNULAR SPACE MONITOR NO SCALE <br /> WRAPPED 4" SCH. 40 GALVANIZED RISE 2"x 18" FLEX CONNECTOR 4" SCH. 40 GALVANIZED STEEL RISER <br /> PRIMED AND WRAPPED MALE SWIVEL/MALE <br /> 3/4" 0 CONDUIT Q WITH CONTAINMENT PRIMED & WRAPPEDMENT BOOT Chevron U.S.A. Inc. ("Chevron") owns the copyright rights to the design of the herein described fueling <br /> TO FLM J-BOX FLEX CONNECTOR system as embodied in any tangible or electronic medium of expression including all building 0 <br /> \�y PHASE II VAPOR RETURN designs, architectural plans and drawings. Thecopyrighted as <br /> TANK FITTIN WITH CONTAINMENT BOOT 1 1 2 the arrangement and omposition of spaces and eements In the design.Iebut hdoes enot incudes individual <br /> rn standard features. Anyone who wishes to copy, distribute or sell this drawing or any derivative works <br /> VENT _-` �" based hereon must have the prior written consent of Chevron, except for copies made for the sole <br /> 4" SCH. 40 GALVANIZED V' (� - purpose of preparing construction drawings for Chevron branded facilities and all such copies shall be Q <br /> PIPE RISER returned to Chevron upon request. <br /> PRIMED & WRAPPED 0 / W <br /> t \ Xe drawings, <br /> r Chevron U.S.A. Inc. All rights reserved. <br /> \\ pc\KVJ The duded s,herein, <br /> are generic <br /> and any specific reference to equipment, materials h components, W <br /> ,- if included herein, are generic and not designed for site specific applications. Chevron does not warrant I- <br /> II 4" SCH, R GALVANIZED EXTRACTOR FITTING 42 OR AB r7yXT`rr or guaranty the accuracy, completeness, merchontablity, intended use or applicability at such drawings, cc <br /> f`u PIPE RISER �J O O <br /> PRIMED & WRAPPED Vk, ,.•PAY•EP ccrA calculations, and any referenced equipment, materials or components, to the requirements or Q <br /> �; needs of your site or local crew. Consult a registered architect or professional engineer to determine <br /> II4" ALUMINUM FILL TUBE :o� F�., any site specific design, applicability, accessibility, building code, municipal requirements and any and <br /> TANK FITTING 45 w/ POSITIVE SHUT OFF— all applicable federal, state end local statutes, rules and regulations which may affect your site. a <br /> DEVICE: INSTALL AT 95% 3" BALL FLOAT VALVE AT 90% 47 ;11C 19291 Chevron does not provide these services. <br /> OF TANK-CAPACITY- - OF TANK CAPACITY MRR 3 0 ?,RQ Q <br /> A (OUTSIDE OF CALIFORNIA & (CALIFORNIA & ARIZONA ONLY) 0 W <br /> v\—ARIZONA)— _�- x sT�i t '.P to o �>\P _' TANK SECTION,TURBINE AND FILL DETAILS = <br /> 46 (C ALUMINUM FILL TUBE PRODUCT FLOAT 0h CA1.1 t Chevron _ <br /> ` <br /> (CALIFORNIA & ARIZONA) � � S. <br /> WATER FLOAT <br /> SIDE VIEW AT TANK BOTTOM CHEVRON SS# - <br /> BOTTOM LOCKING NUT -- <br /> Marketing COLONY DRIVE AND HWY.99 <br /> �-/ RIPON, CA <br /> """— STEEL PLATE AT TANK BORevisions <br /> WIRE INSTALLATION CABLE BOTTOM SCALE: U4'-T-O" DATE: JULY, 00 <br /> SENSOR 87 <br /> DR. CH. APP. <br /> SHEET ANNULAR SPACE MONITOR 6 FILL DETAIL 5 VAPOR AND VENT 4 AUTOMATIC TANK GAUGE C <br /> =1 -G 1 '=1'-0" "=r-o" =r-o"' F-3 u <br />