SIDE "B" (PRODUCT AND VAPOR PIPING SIDE) NOTE: <br /> NOTE: ISOLATION BOOI IS HOT REQUIRED IF THE FLEX CONNECTOR ------------ ........ <br /> IS LOCATED INSIDE A CONTAINMENT SUIMP. <br /> 24" 24" <br /> 0 1. PRODUCT PIPING (HARD) MUST ALWAYS PENETRATE THE DISPENSER SUMP FROM THE OPPOSITE SIDE OF <br /> 3/4" x 1 1/2" <br /> >I OTS' 21 <br /> DISPENSER (8) PROVIDED FOR 9" 1/2" ELECTRICAL CONDUITS, <br /> 10 1/2" 9" <br /> ANCHOR BOLTS <br /> 2, PLUGS ON ALL SHEAR VALVES MUST BE ACCESSIBLE, <br /> 1" N.P.T. VAPOR 112 3, USE RIGID BLACK PIPE (INSTEAD Of:' HOSE) FOR VAPOR INSIDE ALL DISPENSERS. <br /> RECOVERY OUTLET <br /> STEEL ISLAND FORM (BALANCE) ------- 4, INSTALL VAPOR SHEAR SUPPORT FROM BOTTOM OF SHEAR VALVE TO DISPENSER BOX, <br /> 5. PUL.1- BACK REDUCERS IN DISPENSER BOXES AND SUMPS AFTER SECONDARY PIPE HAS BEEN 'TESTED. <br /> FRP CONTAINMENT SUMP -----__,_ 4" RISER 2" SCF-i. 40 FRP BELL X <br /> THREADED MALE COUPLING. <br /> 9" 10 1 /2' I'SOLATION BOOT— - <br /> ------- _X CONNECTOR <br /> Fl E <br /> TESTING: <br /> 0 2" FRP <br /> 6" MAX. HEIGHT AT DISPENSERS TO N I I <br /> ............ 12 <br /> COMPI-Y WI TH ADA REOUIREMENTS I _ ____ - __ -- ''___ ___­ _­ -7____ ­T 45' ELBOW <br /> 6 1� TEST ALL PIPiNG ACCORDING "TO CHEVRON STANDARD CONSTRUCRON SPECIFICATIONS <br /> 2. FILL DISPENSER SUMP WII'H WATER UP TO HIGHESr PENETRATION, <br /> EXTRACTOR FITTING (4 REMOVE WATER WHEN DIRECTED BY CHEVRON PROJECT MANAGER. <br /> 45- <br /> 3- ------ 7V 2" FRP C22)-/ 3. WHEN TESTING PRODUCT I-INES, INSTALL STEEL. CAP ON OPEN <br /> ......... 3" X 2" FRP SHEAR VALVES TO AVOID DAMAGE TO THE VALVE, <br /> 3" REDUCER TEE <br /> SEE DETAIL 8 11.11S SHEET FOR -7 1 1/, NPT INLET (HIGH FEEDSTOCK) 3" FRP <br /> ADDMONAL NOTES 1 1/2" NPI INLET (LOW FEEDS <br /> 6 3/4" <br /> _.._._...1" N.P.T. t <br /> CONDUIT CONDIJIT VENT [RISER <br /> TAP 3 PLACES SUPREME UNLEADED (Typ') 81, <br /> 2"x2"x1/4" GALVANIZED THREADED <br /> 1. CONTRACTOR TO FIELD VERIFY" DISPENSER BASE DIMENSIONS, '91, <br /> 2, PRODUOT ORDER SHOWN IS TYPICAL, NO OTHER VARIATIONS ARE ACCEPTABf E. FEMALE COUPLING WITH PLUG FOR 0 <br /> -TEST PORI, PRIMED & WRAPPED CONCRETE <br /> ---------------- ------ ------------------------------ ----------- ........... .......--- BELOW GRADE ------- COLLAR-------- 4 8" <br /> DISPENSER ON ISLAND 4 DISPENSER BASE DRESSER WAYNE 3/V59O/U 2 PHASE 11 VAPOR LINE CONNEc-rION 2"0 GALVANIZED PIPE, PRIMED <br /> WRAPPED BELOW GRADE ­­----------- <br /> ...... NO SCALE <br /> CONCRETE <br /> DISPENSER JUNCTION BOX (BY MFR,) 2%24" FLEX CONNECTOR COLLAR <br /> WITHIN CONTAINMENT BOOT <br /> NOTE: ISOLATION BOOT IS NOT REQUIRED IF I-FIE FLEX CONNECTOR <br /> *TERMINATE BELOW GRADE* <br /> IS LOCATED INSIDE A CONTAINMENT SUMP. <br /> DISPENSER �6D OF 36" ,-----EXPI-.OSI(,)N PROOF JUNCTION BOX vv <br /> FiLlER <br /> ............ 4 <br /> 1 1/2"0 SCH, 40 BLACK IRON <br /> PIPE RISER C 2" SCI-L �O FRP BELI-------- <br /> .vY___............ <br /> ASPHALT PAVING 6" CONCRETE S_AB <br /> x FEMALE COUPLING <br /> 1 1/2" N.@. f. NLEr ONION —------ SEAL OFFS <br /> BASE MATERIAL,-------- <br /> (BY DISPENSER MFG.) <br /> R OWER/DATA <br /> 2" ERR VENT <br /> --INTERCONA PIPE TO TANK V <br /> SENSOR <br /> .4 <br /> � �! 4 3 SCH, 40 ERR BELL X <br /> DUAL POPPET IMPAC-r VALVE 4' 4 <br /> I MAXIMUM MUM CROWN PER ADA — 4 RISER THREADED MALE COUPLING, <br /> (SF-IEAR SECIION 'TO BE FLUSH ------ <br /> WI -1 TOP OF' DISPENSER ISLAND 4 <br /> 4 > <br /> 4 TZ; <br /> 4n. ASE EFTAIL <br /> 0 ISOLATION BOOT <br /> 4d. ............. I SLOPE DOWN TO TANK <br /> 4 FLEX CONNECTOR 13 Q <br /> 4 <br /> 4 <br /> 11 A 4, z 1/4" PER FT, MIN, SCIAL <br /> < <br /> 4 <br /> OVERALL DIMENSION <br /> I I-I ZE R BAR DETERMINED BY NUMBER <br /> OF' RISERS AND/OR <br /> BRACKET EXTENSION <br /> SUMP PENETRATION BOOT 0 R LOCAL. CODE, <br /> MANIFOLD VENT PIPES <br /> F".R.P, DISPENSER CONTAINMENT SYSTEM �6 .-----PEA GRAVEL z 12'-0" ABOVE GRADE <br /> EXTRACTOR FITTI <br /> FOR CONDOIT i�r11 1 N C PRESSURE VACUUM VALVE Z/ <br /> _Qy\ (_n M 3" FRID 90' ELBOW <br /> 2" x 1 1/2" 90' BLACK IRON ELBOW COI`JDIJIT TO r AS REQUIRED BY LOCAL CODE. <br /> MONITOR SYSTEM FOR <br /> 3 FIR P (�I) 1/4" BEVEL BUTT OVERFILL ALARM & SWI TCF1 <br /> CONTAINMENT SENSOR <br /> 6 I/,o11 WELD--SMOOTH. 11 AS REQUIRED BY LOCAL CODE <br /> 6 )l 2 6 1/2",, /6 1/2"j, <br /> IN, <br /> 314" C O N D U I F 1-0 SALES <br /> CLEAR 4" (11 TUBE FRAME, <br /> -------- AREA FOR INTERCOM <br /> PAINT DARK GRAY <br /> 7 CONDUIT To CONTROL PANEL FOR GY­210 ------------—------ <br /> I POWER AND DATA REGULAR UNLEADED "CH. <br /> 1/2" MINIMUM CLEARANCE 2" 0 S 40 <br /> BETWEEN FITTING & PIPE BRACKET GALVANIZED PIPES <br /> -----FASTEN VENT <br /> 2"0 F�R.P� P (DO NOT PENETRATE SUMP) (PRIMED AND WRAPPED <br /> PIF RISERS SECURELY <br /> BELOW GRADE) <br /> 3" P,V,C- OR ERR PIPE OPEN AT BOTTOM, ------- -__-_---- <br /> '��-(' TO FRAME WITH <br /> ATTACH TO CONTAINMENr Box PAINT DARK GRAY PRE--F"ORMED <br /> GY­210 —---------- <br /> Ir . ....... UNISTRUT BRACKETS, <br /> AS NEEDIED FOR SUPPORT, <br /> ,�Q 3"0 F,R.F', 21 -_ 5 3 2"x2%11/4" GALVANIZED <br /> THREADED FEMALE >� <br /> 00 1 1/2"M x I 1/2"MS x 18" NO SCALE NO SCALE COUPLING WITH PLUG < <br /> 6 1/2" SUMP PENETRATION B T ---LIQUID SENSOR C��)i PIPE TRENCH DETAIL PHASE 11 VAPOR LINE CONNECTION <br /> MINIMUM FLEXIBLE CONNECTOR FOR TEST PORI' Ro _0 PRESSURE/VACUUM <br /> CLEARANCE 3" TO 2" REDUCER BOOP I ,I TYP, VENT VALVE <br /> BETWEEN J NOTE: (a 4 <br /> WITH TEST PORT —------- HOLD FITTING 2" NPT ITIREADS <br /> PIPE CFS� APPROVED NON--HARDENING CONC, COLLAR --------— APPF�OX <br /> (LEAVE BOOTS SEALED FOR FUTURE TESTING) (f)3 TOGETHER WHILE - GALVANIZED FIT IING <br /> JOINT COMPOUND 3" SECONDARY PIPE---- FLUSH W/YARD 1� y 0 . <br /> NOTE: TERMINATE 3" PIPING AS CLOSE TO ELBOW AS FEASIBLE 2 PLACES <br /> 7 <br /> TO ACCOMODAIE FUTURE REDUCER BOOT ACCESS FROM GRADE <br /> 12" 0 CONCREFE <br /> 1.0 .k f <br /> FOR THREADED CONNECTIONS. RE&N CURES, SURFACE 75 F - , - - f___- <br /> Ir <br /> FOOTING, SLOPE <br /> PRODL)c,r BELL MALE F.R.P. T -TOP (I_YP.) <br /> A <br /> THREADED ADAPTOR GALVANIZED NIPPLE <br /> 4 PLACES <br /> 3" MINIMUM INSERTION UNION <br /> /-------APPI-Y ADHESIVE TO FLANGE <br /> OF CONTAINMENT PIPE <br /> INTO CONTAINMENT DO NOT LOCATE VENT RISERS WITHIN: <br /> FITTING7 REQUIRED, 2" MINIMUM CLEARANCE BETWEEN SEE DETAIL <br /> Z CLAIA SHELL FITTINGS (FYP.) GALVANIZED <br /> DISPENSER BUILDING OR BUILDING COLUMNS ABOVE VENT PIPES <br /> 36" 1 <br /> ------------- 7 5'-0" OF ELECTRIC LIGLITS, SIGNS OR <br /> TOR TO PROVIDE OTHER SOURCES OF IGNITION <br /> MANIFOLD DETAIL <br /> GENERAL CONTRAC <br /> RIGID PIPING TO EACH VAPOR RECOVERY 3" F.R,P, 45' ELL 7M <br /> ----------- <br /> BE TESTED PRIOR 70 <br /> STABILIZER BAR <br /> SEALING SECONDARY <br /> 1 1/2" x 1' OPW DUAL POPPET <br /> CA - <br /> 7 VENT RISER DETAIL <br /> MANIFOLD 2" PRIMARY PIPE TO <br /> VAPOR SHUTOFF VALVE ��-xy 3" F.R.P, NIPPLE ------------------ <br /> (SHEAR SECTION TO BE FLUSH 4�1 <br /> Ctdflll TOP OF DISPENSER ISLAND NO SCALE <br /> TINQ 3" F.R.P. FEE <br /> CONTAINMENT FIT <br /> 6' Chevron U.&A. Inc. ("Chevron") owns the copyright rights to the design of the herein described fueling <br /> -IPE (TYP.) -n as embodied in any tangible or electronic rnedi(.,in') of expression including all building <br /> -1 MAXIMUM CROWN PER ADA <br /> 3 F.R.F) P systei > <br /> T <br /> 4,' < � designs, architectural plans and dra�Aings. The copyrighted material includes the overall form as well as <br /> 6 <br /> 4 �4 <br /> standard features. Anyone who wishes to copy, distribute or sell this drawing or any derivative works <br /> the arrangement and composition of spaces and elements in the design, but does not include individual <br /> d. <br /> must have the prior written consent of Chevron, except for copies rnade for the sole <br /> 4 4 PIPE SUPPORT (2_6 based hereon n <br /> -)q construction drawings for Chevron branded facilities and all such copies shall be < <br /> A purpose of preparing <br /> ..... 4 returned to Chevron upon request, <br /> @2000 Chevron U.S,A, Inc. All rights reserved, <br /> 2" x 1 1/2" 90' <br /> BLACK IRON ELBOW <br /> h 'k, <br /> The drawings, calculations, and any specific reference to equipment, materials or components, W <br /> C <br /> kzz�)' ...... if Included herein, are generic and not designed for site specific: applications. Chevron does not warrant <br /> 100 <br /> 6" MINIMUM PEA GRAVEL S <br /> X/ -)Labilty, intended use or applicability of such drawings, <br /> COVER OVER F,R.P. PIFIE or guaranty the accuracy, cornpleteness, r-nerchai <br /> ------ 1/2"M x I 1/2"MS x 18 6/' calculations, and any referenced equipment, Materials or components, to the requirernents or <br /> needs of your site or local area, Consult a registered architect or professional engineer to determine <br /> D <br /> -1'; 19 -ig code, rnunicipal requirernents and any and <br /> r -2t, <br /> any site specific design, applicability, accessibility, buildij <br /> 0 <br /> 3 0 all applicable federal, state and local statutes, rules and regulations which may affect your site, <br /> NOTE: Chevron does not provide these serv:ces, <br /> APPROVED NON--HARDENING <br /> Vru u1 ti'- <br /> JOINT' COMPOUND FOR 71-IREADED <br /> 0 <br /> 0 <br /> CONNECTIONS, <br /> o PRODUCT, VENT, VAPOR PIPING AND DISPIEENSER DETAILS 3: <br /> 2"0 F,R,P. VAPOR RECOVERY PIPE Chevron <br /> BELL x MALE F.R.P. NOTE: <br /> SUMP PENETRATION BOOT THREADED ADAPTOR Chevron <br /> ALL CROSS OVER PIPING TO BE CHEVRON SS# <br /> MADE WITH TEE (OR 90' ELL), <br /> SHORT NIPPLE AND 45' ELL, Marketing COLONY DANE AND HWY, 99 <br /> SLOPE PIPING TOWARD <br /> UNDERGROUND FUEL RIPON, CA <br /> N 01 E STORAGE TANKS AT <br /> 1/4" PER FOOT MINIMUM, Revisions <br /> 1, MOUNT VAPOR SHI-I I OFF ALVE USING PHIL—1-1 FE SCALE- 1/4"-T-0' DATE.: AUGUST, 00 <br /> VAPOR IMPACT VALVE SUPPORT KIT, VAPOR RECOVERY <br /> ...... DR. CH, APP. <br /> PAVING <br /> T R <br /> ------------- --------- ------ ----------------- -------- .................. ------ ----------- <br /> --------- --------- SHEET <br /> 8 <br /> DISPENSER CONNECTION AND PIPING (HARD) PIPING CROSSOVER DETAIL <br /> F-4 <br /> SCALENO SCALE LL <br /> ... ........7 <br />