Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br />CONTINUED <br />Faculty Munn & Perkins <br />Facility 26292 River Road, Escalon <br />Inspection Jul 9, 2010 <br />Name: <br />Address: <br />Date: <br />VIOLATIONS <br /># <br />V <br />v <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations; V = Violation; RV = Repeat violation <br />Specific requirements of HSC 25270.4.5(a) are identified as CFR code sections beginning with 112 <br />27 <br />CFR 112.7(b) <br />SPCC Plan failed to include a description of potential equipment failure (direction, flow rate, quantity), or <br />provide equivalence as allowed by CFR 112.7(a)(2) <br />28 <br />CFR 112.7(c) <br />Failed to provide secondary containment and/or diversionary structures that are capable of containing <br />discharge from primary containment until it is cleaned u <br />Failed to provide explanation, conduct periodic integrity testing of containers and/or periodic integrity and <br />29 <br />CFR 112.7(d) <br />leak testing for valves and piping if containment or discharge prevention structures were determined to be <br />impracticable on an SPCC Plan or sections of one that is PE certified <br />If a response plan was not submitted to the RA, and containment or discharge prevention structures were <br />30 <br />CFR 112.7(d) <br />determined to be impracticable, the SPCC Plan failed to provide: (1) an oil spill contingency plan, (2) <br />written commitment of manpower, equipment, materials to control and remove oil discharge <br />31 <br />CFR 112.7(e) <br />Failed to conduct inspections and tests in accordance with written procedures and/or maintain signed <br />records of inspections and tests as required by the facility's SPCC Plan on site for 3 years <br />32 <br />CFR 112.7(f) <br />Failed to: (1) train personnel on discharge prevention; (2) designate a person to be accountable for <br />dischargeprevention; or 3 schedule prevention discharge prevention briefings at least annual) <br />Failed to describe how the oil handling, processing and storage areas are secured and controlled, how <br />33 <br />CFR 112.7(8) <br />master flow and drain valves are secured; how unauthorized access to starter controls on oil pumps are <br />prevented; how out -of -service and loading/unloading connections are secured; the appropriateness of <br />security lighting; or provide equivalence as allowed by CFR 11 2.7 a 2 <br />Failed to provide sufficient secondary containment capacity for tank car or tank truck loading and <br />34 <br />CFR 112.7(h)(1) <br />unloading area if drainage area is not designed to flow into a catchment basin designed to handle <br />discharges <br />Failed to provide methods to prevent vehicles from departing loading and unloading areas before complete <br />35 <br />CFR 112.7(h)(2) <br />disconnection of transfer lines or provide equivalence as allowed by CFR 112.7(a)(2) <br />Failed to inspect lower-most drains and all outlets of vehicles for discharge prior to filling and departure <br />36 <br />CFR 112.7(h)(3) <br />and take appropriate measures to prevent liquid discharge while in transit or provide equivalence as <br />allowed by CFR 112.7(a)(2) <br />Failed to evaluate field -constructed container for risk of discharge or failure due to brittle facture or other <br />37 <br />CFR 112.7(i) <br />catastrophe after repair, alteration, reconstruction, or change in service, or provide equivalence as allowed <br />by CFR 11 2.7 a 2 <br />SPCC Plan failed to include a complete discussion of conformance to discharge prevention and <br />38 <br />CFR 112.70) <br />containment procedures as listed in part 112 and any applicable more stringent State rules, regulations, <br />and guidelines <br />If a response plan was not submitted to the RA, and secondary containment is not provided for qualified <br />oil -filled equipment, the SPCC Plan failed to: (i) establish and document procedures for inspection or a <br />39 <br />CFR 112.7(k)(2) <br />monitoring program to detect equipment failure and/or discharge, (ii) provide oil spill contingency plan <br />and/or written commitment of manpower, equipment, materials to control and remove oil discharge <br />Failed to prevent discharge into the drainage system from diked storage areas and/or inspect <br />40 <br />CFR 112.8(b)(1) <br />accumulation prior to drainage, or provide equivalence as allowed by CFR 11 2.7 a 2 <br />Failed to use manual, open -and -closed design valves for the drainage of diked areas, or provide <br />41 <br />CFR 112.8(b)(2) <br />equivalence as allowed by CFR 112.7(a)(2) <br />Failed to design facility drainage system from undiked areas to flow into appropriate ponds, lagoons, or <br />42 <br />CFR 112.8(b)(3) <br />catchment basins (in areas not subject to flooding) designed to retain oil or return it to the facility, or <br />provide equivalence as allowed by CFR 11 2.7 a 2 <br />Failed to equip the final discharge of all ditches with a diversion system that would retain oil in the facility in <br />43 <br />CFR 112.8(b)(4) <br />the event of an uncontrolled discharge if CFR112.8(b)(3) is not met, or provide equivalence as allowed by <br />CFR 112.7(a)(2 <br />Failed to provide two "lift" pumps, one permanently installed, where drainage waters are continuously <br />44 <br />CFR 112.8(b)(5) <br />treated in more than one treatment unit, or provide equivalence as allowed by CFR 112.7(a)(2) <br />Container not compatible with oil stored and/or storage conditions, or failed to provide equivalence as <br />45 <br />CFR 112.8(c)(1) <br />allowed by CFR 11 2.7 a 2 <br />Failed to provide sufficient secondary containment capacity for a bulk storage tank that would hold the <br />46 <br />CFR 112.8(c)(2) <br />volume of the largest container plus sufficient freeboard to contain precipitation and/or diked area is not <br />sufficiently impervious to contain discharged oil <br />Allowed drainage of uncontaminated rainwater from a diked area and failed to: (i) keep bypass valves <br />sealed closed; (ii) inspect retained rainwater prior to discharge; (iii) open bypass valve and reseal it under <br />47 <br />CFR 112.8(c)(3) <br />responsible supervision; (iv) maintain adequate records of such events; or provide equivalence as allowed <br />by CFR 112.7a 2 <br />Inspector Phone: <br />Received By: <br />TiOe: <br />lM `1\)14-t,),_ (209) 468-3439 <br />EHD 28-02 Rev 2/19/10 O Wge 2 ` APSA INSPECTION REPORT <br />