My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
7501
>
2800 - Aboveground Petroleum Storage Program
>
PR0539001
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:46 AM
Creation date
10/11/2018 1:57:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0539001
PE
2832
FACILITY_ID
FA0022384
FACILITY_NAME
Eleventh Street Chevron
STREET_NUMBER
7501
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
Tracy
Zip
95304
APN
25014017
CURRENT_STATUS
01
SITE_LOCATION
7501 W ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sdgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: F7501tyNA <br /> iliAddress: Date: <br /> Eleventh Street Chevron ELEVENTH ST, TRACY September 20, 2017 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 703 CFR 112.8(b)(3), Failed to design facility drainage system from undiked areas to retain in the facility V ❑R ❑COS <br /> 12.8(b)(4) <br /> 704 CFR 112.8(b)(5) Failed to provide two lift pumps for more than one continuous treatment unit V ❑R ❑COS <br /> 705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions V ❑R ❑COS <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment V ❑R ❑COS <br /> 707 CFR 112.8(c)(3) Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater V ❑R ❑COS <br /> 708 CFR 112.8(c)(3)(iv) Failed to maintain records of drainage from diked areas V ❑R ❑COS <br /> 709 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks n V in R ❑COS <br /> 710 CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity V ❑R ❑COS <br /> 711 CFR 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified personnel V ❑R ❑COS <br /> 712 CFR 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards n V ❑R ❑COS <br /> 713 CFR 112.8(c)(7) Failed to provide effective leakage control from defective internal heating coils V ❑R ❑COS <br /> 714 CFR 112.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device n V ❑R ❑COS <br /> 715 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation V ❑R ❑COS <br /> 716 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge V ❑R ❑COS <br /> 717 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas D V ❑R ❑COS <br /> 718 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers n V ❑R ❑COS <br /> 719 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge V ❑R ❑COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on n V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation 3 V ❑R ❑COS <br /> 4020 See below Unlisted Training violation 3 V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Itern # Remarks <br /> Page 3 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.