My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2800 - Aboveground Petroleum Storage Program
>
PR0516150
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2018 8:48:09 PM
Creation date
10/15/2018 1:46:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516150
PE
2831
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v" Claytod <br /> z*F75UVM7JC[t <br /> Chuck Peek Page 2 <br /> San Joaquin General Hospital Clayton Proposal No. 04SFOESDO66 <br /> March 15,2004 <br /> collect a second set of confirmation samples. If deeper contamination is present,the <br /> Hospital and Clayton will also determine whether groundwater samples are necessary. <br /> SCOPE OF WORK <br /> The proposed scope of work is based on the assumptions below. <br /> • Clayton will collect up to twelve samples during two visits to the site, six samples per <br /> visit. The shallow depth of the excavation will allow us to collect the samples using a <br /> hand auger. A GeoProbe or similar drilling equipment will not be required. Samples <br /> will be collected on each sidewall and the bottom of the excavation. In addition, <br /> Clayton will collect one composite sample from the 55-gallon drums that may be <br /> used to characterize the excavated soil for disposal. <br /> • We will analyze the samples using EPA Method 8260B for total petroleum <br /> hydrocarbons as gasoline(TPH-g);benzene,toluene,ethylbenzene, and xylene <br /> (BTEX), and five fuel oxygenates, including MTBE. The analyses will be provided <br /> using a standard turnaround time with no rush charges. The samples will be analyzed <br /> by STL, a state-certified laboratory, located near our office in Pleasanton,California. <br /> • The Hospital will be able to provide a site plan that will be used in the report. We <br /> would prefer to receive an electronic file either in AutoCAD or CorelDraw if <br /> available. <br /> • The Hospital will be able to identify any underground utilities in the area of the <br /> sampling and therefore use of a utility locator will not be required. Since shallow <br /> hand augering will be completed,we have assumed an excavation permit will not be <br /> required by neither the County nor the City for the initial sample event. If a permit is <br /> required at a later date, Clayton will discuss the additional costs with the Hospital and <br /> obtain authorization prior to proceeding. <br /> The proposed scope of work consists of four Tasks, including pre-field activities, field <br /> activities, laboratory analysis, and project management/report preparation. These Tasks <br /> are described in the following subsections. <br /> TASK 1: PRE-FIELD ACTIVITIES <br /> Clayton will prepare a Site-specific Safety and Health Plan(SSHP)to reflect the <br /> fieldwork proposed at the subject property. The SSHP will detail the work to be <br /> performed, safety precautions, emergency response procedures, nearest hospital <br /> information, and onsite personnel responsible for managing emergency situations. <br /> SAESTroposals\2004\04.066 San Joaquin County.dm <br />
The URL can be used to link to this page
Your browser does not support the video tag.