My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3003
>
2800 - Aboveground Petroleum Storage Program
>
PR0516435
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 3:50:03 PM
Creation date
10/16/2018 9:54:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516435
PE
2834
FACILITY_ID
FA0007088
FACILITY_NAME
TESORO STOCKTON TERMINAL
STREET_NUMBER
3003
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
145-030-10
CURRENT_STATUS
01
SITE_LOCATION
3003 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t + <br /> San Joaquin County AMENUD <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TESORO STOCKTON TERMINAL 3003 NAVY DR, STOCKTON I November 04 2015 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V c R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ■V ❑R COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations V R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R n COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CFR 112.3(d) Plan certification by a Professional Engineer (PE) missing or incomplete. <br /> The Professional Engineer (PE) certification is incomplete. The PE certification on the reviewed Spill Prevention <br /> Control and Countermeasure (SPCC) plan is conditional on the outstanding and necessary Aboveground Petroleum <br /> Storage Act(APSA) tank system related repairs. The PE certification must not be conditional and must include all of <br /> the aspects in 40 CFR 112.3(d)(1), including attesting that the PE is familiar with 40 CFR Part 112, he or his agent <br /> has visited and examined the facility, the Spill Prevention, Control, and Countermeasure (SPCC) Plan has been <br /> prepared in accordance with good engineering practice, including consideration of applicable industry standards, <br /> procedures have been established for required inspections and testing, and the Plan is adequate for the facility. <br /> Immediately obtain a complete PE certification for the facility's SPCC Plan. Submit a copy of the completed <br /> certification to the EHD. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): ;��.(I�C� STACY RIVERA, Senior REHS (209)468-3440 11/04/2015 <br /> Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.