My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2941
>
2800 - Aboveground Petroleum Storage Program
>
PR0527865
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2020 1:57:09 PM
Creation date
10/16/2018 10:34:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527865
PE
2835
FACILITY_ID
FA0009657
STREET_NUMBER
2941
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206-1149
APN
48906-1
CURRENT_STATUS
01
SITE_LOCATION
2941 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
j San .loaquin County <br /> Environmental Health Department <br /> i 1868 East Hazelton Avenue. Stockton. California 95205-6232 I <br /> i Teleohone: (2091468-3420 Fax: (209) 468-3433 Web:vwvvv.siaov.ora/ehd i <br /> Aboveground Petroleum Storage Act Inspection Repot i <br /> Facility Name: I Facility Address: I Date: I <br /> NUSTAR TERMINALS OPERATIONS 12941 NAVY DR, STOCKTON February 24, 2015 { <br /> General Reqtl-e!nents for SPCC Plans <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years ❑V ❑R ❑COS ; <br /> 614 CFR 112.7(f)(1) Failed to train personnel on discharge prevention n V jiR i i COS <br /> 615 CFR 112.7(0(2) Failed to designate a person accountable for discharge prevention e V c R e COS <br /> 616 CFR 112.7(f)(3) Failed to schedule and conduct discharge prevention briefings at least annually n V n R e COS I <br /> 617 CFR 112.7(8) Plan failed to address security of site and valves, lock out/tag out,and lighting ❑V ❑R ❑COS <br /> 618 CFR 112.7(h)(1) Loading/unloading rack containment system not properly sized u V u R u COS <br /> , <br /> 619 CFR 112.'(h)(2) Failed to provide vehicular departure system loading and unloading racks ❑V ❑R ❑COS <br /> 620 CFR 112.7(h)(3) Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles o V ❑R ❑COS <br /> 621 CFR 112.7(i) Failed to evaluate field constructed container for brittle fracture and take appropriate action e V c R c COS <br /> 9 622 CFR 112.70) I Failed to include discussion of conformance to discharge prevention and containment procedures ❑V u R ❑COS <br /> SPCC Plan Regtiirements for Onshore Facilities (excluding prodti'ction facilities) I, <br /> 701 I CFR 112.8(b)(2) Failed to use manual open-and-closed design valves for the drainage of diked areas u V u R L COS <br /> 702 CFR 112.8(b)(3), Failed to design facility drainage system from undiked areas to retain in the facility u V ❑R ❑COS <br /> 112.8(b)(4) <br /> 703 CFR 112.8(b)(5) Failed to provide two lift pumps for more than one continuous treatment unit ❑V ❑R ❑COS <br /> 704 CFR i 12.8(c)(2) Diked area is not sufficiently impervious to contain discharged oil tjV , R i i COS <br /> 705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions ❑V ❑R ❑COS <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment c V ❑R ❑COS <br /> 707 CFR 112.8(c)(3)(i) Failed to keep containment bypass valves closed when not draining rainwater ❑V ❑R ❑COS <br /> 708 CFR 112.8(c)(3)(ii) Failed to inspect retained rainwater prior to discharge c V c R c COS <br /> 709 CFR 112.8(c)(3)(iii) Failed to open and Gose bypass valve to drain rainwater under responsible supervision IIV u R u COS <br /> 710 CFR 112.8(c)(3)(iv) Failed to maintain records of drainage from diked areas L,V ❑R ❑COS <br /> 711 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks ❑V ❑R ❑COS <br /> 712 CFR 112.8(c)(6) Failed to perform tank inspections that take into account size,configuration;and design ❑V ❑R ❑COS <br /> 713 CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel u V ❑R u COS <br /> 714 CFR 112.8(c)(6) Failed to test and inspect containers by appropriately qualified personnel after material repairs ❑V c R ❑COS <br /> 715 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils u V u R u COS <br /> 716 CFR 112.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device ❑V e R e COS <br /> 717 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation ❑V ❑R c COS <br /> 718 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge u V ,R u COS i <br /> 719 CFR 112.8(c)(10) Failed to promptly correct visible discharges and!or remove accumulations of oil in diked areas n V c R n COS , <br /> 720 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers ❑V ❑R ❑COS I <br /> 721 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge ❑V e R o COS <br /> 722 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V e R e COS <br /> --� <br /> Received by 0nitiai): I inspector: Phone: Date: i <br /> STACY RIVERA, Senior REHS 8 I (209)468-3440 02/24/2015 f <br /> Faye 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.