Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue. Stockton. California 95205-6232 I <br /> Telerhone: (209)468-3420 Fax: (209'1468-3433 Web:www siaov.ora/ehd i <br /> L <br /> Aboveground Ae'r0lle- ��i �I . L Inspection Repoft <br /> I <br /> ! I ! <br /> Facility Name: I Facility Address: r Date: I <br /> j NUSTAR TERMINALS OPERATIONS 12941 NAVY DR, STOCKTON I February 24, 2015 j <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) , <br /> ` 7 3 !1 C112.8(d)(1) I d i e ellbUri f 1 \ ! <br /> 2., C R I Failed to provide corrosion prct� .or buries piping i_i R ❑COS <br /> 724 1 CFR 112.8(d)(2) I Failed to capiblank-flange connection at transfer point and mark its origin if not in service ,V R COS <br /> 1 <br /> /2b U VK 112.dta)v i-ailed to aesign pine supports to minimize abrasio ,corrosion ano to allow for e`"'a^slOn ContraCIlO^ 1 R ❑t 'ti <br /> 726 j CFR 112.8(d)(4) I Failed to reqularly inspect aboveground valves,piping, and appurtenances ❑V n1 R ❑COS <br /> � r <br /> 727 CFR i 12.8(d)(4) Failed to conduct integrity and leak test on buried pipiny ally time it is worked on n V l R ClCtoS ! <br /> 728 CFR 112.8(d)(5) I Failed to adequately warn vehicles entering facility to protect piping and other transfer operations u V -R u COS <br /> I <br /> ether Violations <br /> 4010 See below Unlisted Admiriistrationiuocumentatior violation ( u V u R u COS <br /> 4020 I See below Unlisted Training violation _ _ - _ 1 V ❑R ❑COS I <br /> ! 4037 vee below Unlisted Vpe(atiO <br /> lS%fAlalnteraIIUC V,G tIV1i u V _�R u CCS <br /> anon See helow 11_lnligted RBIPa$P_./Leaks/Spills viniation n V i,R COS <br /> SUMMARY OFF VIOLATIONS I <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> 114nm 3f I Remarks I <br /> 1 I <br /> 1303 ;CFR 'I 11.2.55(c) Failed to have a PE certify technical amendments. <br /> '.The Professional Engineer (PE) certification is dated January 25, 2012 . The Spill Prevention, Control, and <br /> I Countermeasure (SPCC) Plan was amended on September 5, 2013 to include the following changes: Removal of a <br /> permanently closed' tank and installation of a 5,400 gallon shop-fabricated steel tank. These amendments are <br /> technical changes, requiring a PE certification within six months of amendment. A technical amendment is a I <br /> Xchange to the facility, tanks, procedures, materials, construction, design, or maintenance that materially increases <br /> for decreases the facility's potential for oil discharge. Immediately obtain a complete PE certification for the facility's <br /> SPCC plan. Submit a copy of the completed, certified SPCC plan to the EHD for review. This is a Class II violation. <br /> I <br /> j 605 1 CFR 112.7(a)(3) Plan tailed to address facility layout, operations discharge prevention methods and containers. ! <br /> !The transmix drums were not included in the SPCC Plan. Six 55 gallon drums of transmix were observed in the 1 <br /> hazardous waste storage area. The following shall be addressed in the Spill Prevention, Control, and <br /> !Countermeasure (SPCC) Plan: I <br /> I I -type of oil in each fixed container and it's storage capacity. For mobile or potable containers, the type of oil and <br /> II storage capacity for each container or an estimate of the potential number of mobile or portable containers, the I <br /> types of oil, and anticipated storage capacities f <br /> -discharge prevention measures including procedures for routine handling of products I <br /> fI discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a i <br /> discharge i <br /> i -countermeasures for discharge discovery, response, and cleanup I <br /> I - methods of disposal of recovered materials I <br /> -contact list and phone numbers for the facility response coordinator, National Response Center, cleanup <br /> r <br /> !contractors, and all appropriate Federal, State, and local agencies. I <br /> I Immediately amend the SPCC Plan to include all required information. This is a repeat violation, Class II. i <br /> I <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> Received by(initial): Inspector: Phone: Date: <br /> I7 I STACY RIVERA, Senior REHS '� I (209) 468-3440 02/24/2015 <br /> Page 3 of 4 <br />