SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.s1gov.or /q ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Names Stockton Maintenance Station Address 1604 S. B St., Stockton Date- <br /> VIOLATIONS Jun 29, 2011 <br /> VIOLATIONS <br /> R HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations;V=Violation;RV=Repeat violation <br /> # Vv Code Section Specific requirements of HSC 25270.4.5 a are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 X CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2 <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils, or provide equivalence <br /> as allowed by CFR 11 2.7(a)(2) <br /> 50 X CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 112.7(a)(2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> dischar e,or rovide equivalence as allowed by CFR 11 2.7 a 2 <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> e uivalence as allowed by CFR 11 2.7 a 2 <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed,or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or rovide equivalence as allowed by CFR 112.7(a)(2) <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> i' <br /> i' <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Phone. Received By. Title <br /> 1 (209) 468-3440 <br /> i <br /> EHD 2 ev 2/19/10 /Page 3 APSA INSPECTION REPORT <br />