My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BACON ISLAND
>
17251
>
2800 - Aboveground Petroleum Storage Program
>
PR0516704
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2018 5:26:37 PM
Creation date
10/17/2018 2:44:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516704
PE
2831
FACILITY_ID
FA0001818
FACILITY_NAME
BULLFROG LANDING MARINA
STREET_NUMBER
17251
STREET_NAME
BACON ISLAND
STREET_TYPE
RD
City
STOCKTON
Zip
95219
APN
12917003
CURRENT_STATUS
01
SITE_LOCATION
17251 BACON ISLAND RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment 2A <br /> Citation Deficiency Plan Field <br /> 112.7(h)(3) No inspection of lowermost drainstoutlets prior to filling and departure of any tank car/truck <br /> 112.7(1) Plan has no or inadequate procedures to evaluate brittle fracture or catastrophic failure <br /> 112.7Q) No discussion of conformance with applicable State rules,regulations,and guidelines <br /> 112.7(k) Oil-filled operational equipment(OFOE)has no or inadequate secondary containment in <br /> accordance with 112.7(c)and does not meet eligibility criteria in 112.7(kx1) <br /> 112.7(k)(2)(i) No established and documented procedures for inspections or monitoring program for <br /> qualified OFOE to detect equipment failure and/or a discharge <br /> 112.7(k)(2)(i/)(A) No or inadequate:contingency plan per 40 CFR part 109 or FRP under 112.20 <br /> 112.7(k)(2)(ii)(8) No written commitment of manpower,equipment,and materials <br /> 112.8(b)(1) Drainage from diked areas not restrained by valves or manual pumps/ejectors <br /> 112.8(b)(2) Valves used to drain diked areas are not of manual,open-and-dosed design <br /> 112.8(b)(3) ! Drainage from undiked areas not designed to flow to ponds,lagoons,or catchment basins <br /> inside facility,or catchment basins located in area subject to periodic flooding <br /> 112.8(b)(4) No diversion systems to return spills to the facility <br /> 112.8(b)(5) Two'lift"pumps not provided if more than one treatment unit needed or facility drainage <br /> not engineered to prevent discharge as described in 112.1 b CJr <br /> 112.8(c)(1) Material/construction of containers not compatible wi oil stored and/or s "°" ons <br /> 112.8(c)(2)or No secondary containment or inadequately sized to contain Largest single container with <br /> 112.6(a)(3)(ii) freeboard for precipitation. <br /> 112.8(c)(2) Materials or construction of secondary containment are not sufficiently impervious <br /> 112.8(c)(3)(i) Bypass valve not sealed dosed when drainage is to a storm drain or open watercourse <br /> 112.8(c)(3)(ii) Retained rainwater not inspected to ensure presence will not cause a discharge <br /> 112.8(c)(3)(ki) Bypass valves not opened and later resealed under supervision <br /> 112.8(c)(3)(ty) Adequate records of drainage events are not maintained <br /> 112.8(c)(4)& Completely or partially buried metallic tanks are not protected from corrosion or are not <br /> 112.8(c)(5) subject to regular leak testing <br /> 112.8(c)(6) Aboveground containers not integrity tested on a regular schedule or when repaired. <br /> 112.8(c)(6) Testing/inspection not in accordance with industry standards to Identify the appropriate <br /> qualifications for inspectioriftesting personnel or frequency or type of testing/inspection <br /> 112.8(c)(6) Containers and container supports not inspected. <br /> 112.8(c)(6) Outside of container not frequently inspected for signs of deterioration,or oil discharges <br /> 112.8(c)(6) No records of inspections/tests or comparison records not kept <br /> 112.8(c)(7) Steam return and exhaust lines of internal heating coils which discharge into an open <br /> water course are not monitored or passed through a separation system <br /> 112.8(c)(8)or No liquid level sensing devices or other overfill prevention systems provided or not <br /> 112.6(8)(3)(/1/) regularly tested _ <br /> 112.8(c)(9) Effluent treabnent facilities which discharge directly to waters not observed frequently <br /> enough to detect system upsets <br /> 112.8(c)(10) Leaks in diked area are not promptly corrected or oil in diked areas not removed <br /> 112.8(c)(11)or Mobile or portable containers not positioned to prevent discharge as described in 112.1(b) <br /> 112.6(a)(3)(ii) or nolinadequate secondary containment for mobile or portable containers. <br /> 112.8(d)(1) Buried piping installed or replaced after August 16,2002 is not corrosion protected <br /> 112.8(d)(1) Exposed buried piping not inspected for detenoration or corrected <br /> 112.8(d)(2) Out-of service or standby piping not capped or blank flanged or marked as to origin <br /> 112.8(d)(3) Pipe supports not properly designed <br /> 112.8(d)(4) Aboveground valves,piping,and appurtenances not inspected _ <br /> 112.8(d)(4) Buried piping not integrityfleak tested when installed,modified, relocated,or replaced <br /> 112.8(d)(5) Vehicles not warned of aboveground piping or other oil transfer operations <br /> 112.20(e) No certification of the applicability of the substantial harm criteria <br /> Deficiencies found during the inspection are marked with an"X" <br />
The URL can be used to link to this page