COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 11:15:30 AM
Creation date
10/19/2018 3:11:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2014 - 2015
FileName_PostFix
2014 - 2015
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
We will verify that the secondary product pipe slopes back to the UDC and that any leaks flow to the UDC and <br />trigger the liquid sensor. Will the secondary lines open into the UDCs? <br />2. What are you using for backfill around the UDCs and pipe? I assume the existing pea gravel will be reused. Will <br />you use additional pea gravel as necessary to meet the piping and UDC manufacturer instructions? <br />NOV / Red Thread IIA pipe install instructions <br />In all cases, the pipe must be completely surrounded with select backfill (sand, 1,;8" to 'R 4" pea gravel, or <br />crushed stone). There should not be any voids under or around the pipe. Six inches (150 mm) of the fill mu <br />the pipe as bedding material. Native backfill materials should never be used. <br />TABLE 5. Recommended Minimum Burial Depths Based on Soil Modulus of 1,000 psi o <br />(Refer to ASTM D3839 or AWWA C950 for MethodrTheory) <br />Bravo UDC install instructions <br />A.3) Shovel a wide bed of peagravel under the l <br />Thank you, <br />Minimum <br />Min. Amount of Sand. P, <br />Pipe Size <br />Burial Depth <br />Crushed Stone Above T <br />Surface Condition <br />A <br />B <br />In. <br />mm <br />In. <br />mm <br />In. <br />r <br />L <br />51'J <br />Unpaved <br />17 <br />432 <br />12 <br />Paved, min. 4" (100 mm) asphalt <br />12 <br />305 <br />8 <br />Paved, min. 4" (100 mm) concrete <br />9 <br />229 <br />5 <br />1 <br />Paved, min. 6" (150 mm) concrete <br />9 <br />229 <br />3 <br />t <br />75 <br />Unpaved <br />20 <br />508 <br />14 <br />Paved, min. 4" (100 mm) asphalt <br />13 <br />330 <br />9 <br />t <br />Paved; min. 4" (100 mm) concrete <br />11 <br />279 <br />7 <br />1 <br />Paved, min_ 6" (150 mm) concrete <br />10 <br />254 <br />4 <br />1 <br />4 <br />'i -,) <br />Unpaved <br />20 <br />508 <br />14 <br />Paved, min. 4" (100 mm) asphalt <br />14 <br />356 <br />10 <br />2 <br />Paved, min. 4" (100 mm) concrete <br />11 <br />279 <br />7 <br />1 <br />Paved, min. 6" (150 mm) concrete <br />10 <br />254 <br />4 <br />1 <br />F; <br />150 <br />Unpaved <br />36 <br />914 <br />14 <br />Paved, min_ 4" (100 mm) asphalt <br />24 <br />610 <br />10 <br />Paved, min. 4" (100 mm) concrete <br />20 <br />502 <br />7 <br />1 <br />Paved. min. 6" (150 mm) concrete <br />16 <br />406 <br />4 <br />1 <br />Bravo UDC install instructions <br />A.3) Shovel a wide bed of peagravel under the l <br />Thank you, <br />
The URL can be used to link to this page
Your browser does not support the video tag.