Laserfiche WebLink
R�CEIi/E: <br />­,'' <br />11. PIPING SUMP TESTING 0 6 2014 <br />Test Method Developed By: Sump Manufacturer Industry Standard X Profen IMENT <br />LOther (Spec) HEALTH DEPARTMENTG%1 <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Sump # I <br />Sump # 2 <br />Sump # 3 <br />Sump # 4 <br />Sump Diameter: <br />42" <br />42" <br />42" <br />42" <br />Sump Depth: <br />73 '/z" <br />73 %2" <br />73 '/2" <br />75" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />21" <br />22" <br />19" <br />12" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />38" <br />29" <br />38" <br />29" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested' <br />Water Line 55" <br />Water Line 55" <br />Water Line 57" <br />Water Line 52" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />No <br />No <br />No <br />No <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?* <br />No <br />No <br />No <br />No <br />Was fail-safe verified to be <br />operational?* <br />N/A <br />N/A <br />N/A <br />N/A <br />Wait time between applying water <br />and starting test: <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />2:20 <br />2:30 <br />12:10 <br />12:05 <br />Initial Reading (R,): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />2:50 <br />3:00 <br />12:40 <br />12:35 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />verified functional after testin ? <br />Yes <br />Yes <br />Yes <br />Yes <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />