My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
3310
>
2800 - Aboveground Petroleum Storage Program
>
PR0528487
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 11:16:16 AM
Creation date
10/19/2018 4:24:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528487
PE
2832
FACILITY_ID
FA0009490
FACILITY_NAME
KENTS OIL SVC INC
STREET_NUMBER
3310
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
14339005
CURRENT_STATUS
01
SITE_LOCATION
3310 E MINER AVE
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N J O A Q U I N Environmental Health Department <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KENTS OIL SVC INC 3310 E MINER AVE, STOCKTON September 12, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment. <br /> The 150 gallon single walled diesel tank near the area referred to as the"tank farm"was observed with insufficient <br /> secondary containment. The 2,100 gallon double walled diesel container was observed with pitting on the outer <br /> shell, there was no mention of this by the P.E. engineer or on the monthly inspections. Ensure that the outer shell of <br /> the double walled tank is capable of containing the contents of a release. The secondary containment wall for the <br /> 150 gallon tank had loose and damaged concrete blocks. All bulk storage tanks must be provided with a secondary <br /> means of containment for the entire capacity of the tank and sufficient freeboard to contain precipitation. <br /> Immediately provide sufficient secondary containment for this and all other tanks at this facility. <br /> This is a Class 11 violation. <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> The six 55 gallon heat transfer oil drums located in the 'old shop"were observed with insufficient secondary <br /> containment. The drums were observed stored on wooden pallets without a discernible secondary containment. <br /> Portable oil storage containers must be positioned or located to prevent a discharge and shall be furnished with a <br /> secondary means of containment sufficient to contain the capacity of the largest single container with sufficient <br /> freeboard to contain precipitation. Immediately provide sufficient secondary containment for this and all other <br /> portable containers at this facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by October 12, 2018. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: September 12, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209) 953-6213 <br /> Lance Coleman, Operations Manager <br /> FA0009490 PR0528487 SCO01 09/12/2018 <br /> EHD 28-01 Rev.09/10/2018 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.