' San Joaquin County AMENDED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 J2 Z11 _ <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A ONE GAS & FOOD 1574 W GRANT LINE RD, TRACY December 19, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br /> where monitoring will be performed. The site plan was missing the locations of the annular sensors. During the <br /> inspection the annular sensors were added to the site plan and the revised site plan was uploaded into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans was not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. The revised monitoring plans were downloaded from California Environmental <br /> Reporting System (CERS) and placed in the binder during the inspection. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 87-product submersible turbine pump (STP) sump, and in all four under dispenser <br /> containment(UDC) sumps. If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. The service technicians removed approximately three cups of liquid <br /> from the 87-product STP sump and approximately one-half cup of liquid from each UDC. Ensure that all sumps are <br /> maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 91-product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 18, 2017. <br /> Inspector arrived at the site at 8:40 a.m. for an 8:30 a.m. appointment. Service technicians had already <br /> FA0003164 PR0231405 SCO01 12/19/2016 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />