COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
2700
>
2200 - Hazardous Waste Program
>
PR0538796
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2020 4:35:55 PM
Creation date
10/31/2018 11:40:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0538796
PE
2220
FACILITY_ID
FA0022274
FACILITY_NAME
Weyerhaeuser Stockton DC
STREET_NUMBER
2700
Direction
S
STREET_NAME
CALIFORNIA
STREET_TYPE
St
City
Stockton
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
2700 S California St
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\2700\NO PR#\COMPLIANCE INFO\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Small Quantity Hazardous Waste Generator Inspection Report <br />Date: <br />September 25, 2018 <br /> Facility Address: <br /> 2700 S California St, Stockton <br /> Facility Name: <br /> Weyerhaeuser Stockton DC <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 111 CCR 66262.42(a)(c)(d) Failed to comply with uniform hazardous waste manifest exception requirements. <br />Manifest numbers: 005105826SKS (10/29/15), 005895454SKS (5/12/2017), and 005863025SKS (5/12/2017) were <br />found without a signed off copy from the destination facility. Manifest number 006099834SKS (5/19/2017) was not <br />found on site. Hazardous waste generators shall retain copies of all manifests signed off by the destination facility <br />on site for three years and have them readily available for review. If the generator did not receive a copy of the <br />manifest with the handwritten signature of the owner or operator of the facility to which the generator’s waste was <br />submitted within 60 days of the date the waste was accepted by the initial transporter, the generator shall submit a <br />legible copy of the missing manifest, with some indication that the generator has not received confirmation of <br />delivery. This information shall be submitted to: <br /> DTSC Report Repository <br /> Generator Information Services Section <br /> P.O. Box 806 <br /> Sacramento, CA 95812-0806 <br />Immediately locate a copy of the missing manifests or prepare and submit the required information to DTSC. <br />Submit to the EHD a copy of the signed off copy of the manifest or a copy of the information submitted to DTSC. <br />This is a Class II violation. <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br />Copies of hazardous waste disposal records for 2016 were not found on site. In addition, records indicate that <br />there was only one pickup event of hazardous waste for 2017 (5/12/2017) and two for 2018 (2/8/2017 and <br />2/13/2018). Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and <br />all receipts used in a consolidated manifesting procedure on site for three years and have them readily available for <br />review. Immediately locate a copy of all manifests and receipts for the last three years, maintain them on site, and <br />submit copies of all hazardous waste disposal records (including universal waste) for 2016, 2017 and 2018 to the <br />EHD. <br />This is a minor violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br />waste. <br />In storage area one (area closest to the office): <br />-Two black 55 gallon steel drums containing oily debris/oily containers (both over 1/2 full) were observed not <br />completely shut. <br />In storage area two (near the lockers): <br />-Two black 55 gallon drums containing oily debris/oily containers were observed overfilling. <br />-One black 55 gallon drum containing oily debris/oily containers was observed not completely shut. <br /> All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately <br />close these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br />This is a minor violation. <br />Page 5 of 7 <br />FA0022274 PR0538796 SC001 09/25/2018 <br />EHD 22-01 Rev. 09/22/16 Small Quantity Hazardous Waste Generator OIR