BUFFER ZONE•CREDiT$
<br />The bufferzone distances for Sectagon 42 applications maybe reduced by the percentages
<br />listed below. Credits may be added, but credits cannot exceed 80%. Also, the minimum
<br />bufferzone distance is 25 feet regardless of buffer zone credits available.
<br />• See http://www.epa.gov/pesticides/tarperedits/ for a list of tarps that have been tested
<br />and determined to quality for buffer reduction credits. Only tarps listed on this website
<br />qualify for buffer reduction credits.
<br />• 10% reduction In buffer zone distance; IF the.organic content of the soil in the application
<br />block is a 1% - 2%; a 20% reduction is bufferzone distance; IF the organic content of the
<br />soil in the application block is>2%- 3%; and a 30% reduction in the bufferzone distance,
<br />IF the organic content of the soil In the application.block is >3%,
<br />• 10% reduction in buffer zone distance, IF the soil temperature is measured to be 50°F or
<br />less. Record temperature measurements -at the application depth or 12 Inches, whichever
<br />Is shallower.
<br />• 10% reduction in the buffer zone distance, IF the clay content of the soil in the.application
<br />block is greaterthan.27%.
<br />Examples of Buffer Zone Calculations; with Credits Applied
<br />It the buffer zone is 50 feet and the application qualifies for a buffer zone reduction credit
<br />since the soft organic content Is 1,5%, then the buffer zone can be reduced by 10%, i.e.,
<br />reduced by 5 feet based on following calculation: 50.feet— (50 feet x10%) = 45 feet
<br />If the bufferzone is 50 feet and the application qualifies for two bufferzone credits since the
<br />soilorganic content is 1.5% and the clay content is greater than 27%,then the buffer zone
<br />can beYeduced by 20•% 10%organic content credit + 10% clay content credit), i.e., reduced
<br />by 10 feet based on the following calculation 50 feet - (50 feet x 20%) = 40 feet.
<br />POSTING FUMIGANT BUFFER ZONES
<br />• Posting of a buffer zone is required unless there is a physical barrier that prevents
<br />bystanderaccess to the bufferzone,
<br />• Buffer"Zone signs must be placed along or outside the perimeter of the buffer zone, at
<br />all usual points of entry and along likely routes of approach from areas where people not
<br />under the owner's control may approach the buffer zone.
<br />o Some examples of points of entry include, but are not limited to, roadways, sidewalks,
<br />paths, and bike trails.
<br />o Some examples of likely routes of approach include, but are not limited to, the area
<br />between a buffer zone and a roadway, or the area between a bufferzone. and a housing
<br />development
<br />o. When posting, the certified applicator supervising the application must ensure
<br />compliance with all local laws and regulations.
<br />• Buffer Zone signs must meet the following criteria:
<br />o The printed side of thesign must face away from the application block. toward areas
<br />from which people could approach.
<br />o Signs, mustTemain legible during the entire posting period and must meet the general
<br />standards outlined in the WPS for sign size, text size, and legibility (see 40 CFR
<br />§170:120).
<br />o Signs must be posted no sooner than 24 hours prior to the start of the application and
<br />remain posted until the buffer zone period has expired.
<br />o Signs must be removed within 3 days after the end of the buffer zone period,
<br />o Buffer Zone signs which meet the criteria above. will be provided at points of sale.
<br />for applicators to use. Templates may downloaded from http:!/www.epa.gov/
<br />pesticideslrereaistration/spit fumfaants/.
<br />Q The Buffer Zone signs must contain the following information:
<br />■ The 'Do Not Walk' symbol
<br />■ DO NOT ENTER/NO ENTRE,
<br />• Metam Sodium Sectagon 42 Fumigant B4FFER ZONE,
<br />a Contact information for the certified applicator in charge of the fumigation.
<br />Exception: if multiple contiguous blocks are fumigated within a 14 -day period, the "entire
<br />periphery of the contiguous blacks' buffer zones may be posted. Buffer Zone signs must
<br />be posted no sooner than 24 -hours prior to the startorthe first application. The signs must
<br />remain posted until the last buffer zone period expires and signs must be removed within
<br />3 -days after the buffer zone period for the last block has expired,
<br />RESTRICTIONS FOR DIFFICULT TO EVACUATE SITES
<br />Difficult to evacuate sites are pre -K to grade 12 schools, state licensed daycare centers,
<br />nursing homes, assisted living facilities, hospitals, in-patient clinics, and prisons:
<br />• No fumigant ap fication with a buffer zone greater than 300 feet is permitted within 1/4
<br />mile (1320 feet of difficult to evacuate sites unless the site is not occupied by children
<br />from state -licensed day care centers, students (pre -K to grade 12), patients, or prisoners
<br />during the application and the 36 -hour period following the end of the application.
<br />• No fumigant application with a buffer zone of 300 feet or less is permitted within 1/8 mile
<br />(660 feet) of difficult to evacuate sites unless the site Is not occupied by children from
<br />state -licensed day care centers, students (pre-Kto grade 12), patients, oriodsoners during
<br />the application and the 36 -hour period following the end, of the application.
<br />Scaagon42 20131ndd 25
<br />AUG 31 2015
<br />EMERGENCY PREPAREDNESS AND RESPONSE MEASURES
<br />If the buffer zone is 25 feet; then the Emergency Preparedness and Response,
<br />Measures are not. applicable.
<br />If the buffer zone is 25 feet, then the Emergency Preparedness and Response
<br />Measures are not applicable.
<br />Triggers for Emergency Preparedness and Response Measures
<br />The cergtied applicator must either follow the directions under the Fumigant Site Monitoring
<br />section or follow the directions under the Response Information for Neighbors section If:
<br />• the buffer zone is greater than 25 feet but less than or equal to 100 feet, and there are
<br />residences or businesses within 50 feet from the outer edge of the bufferzone, or
<br />• the buffer zone is greater than 100 feet but less than or equal, to 200 feet, and there are
<br />residences or businesses within 100 feet from the outer edge of the buffer zone, or
<br />• the buffer zone is greater than 200 feet but less than or equal to 300 feet, and there are
<br />residences or businesses within 200 feet from the. Duter edge of the buffer zone, or
<br />• the buffer zone is greater than 300 feet or the buffer zones overlap, anal there are
<br />residences or businesses within 300 feet from the outer edge of the buffer zone.
<br />Fumigant Site Monitoring
<br />NOTE: Fumigant Site Monitoring is ONLY required if the Emergency Preparedness
<br />and Response Measures are triggered AND directions from the Response
<br />Information for Neighbors section are not followed.
<br />From the start of the application until the buffer zone period expires, .a certified applicator or
<br />handler(s) under his/her supervision must:
<br />• Monitor for sensory irritation In areas, between the buffer zona outer perimeter and
<br />residences and businesses that trigger this requirement:
<br />• Monitoring for sensory irritation must begin in the evening on the day of application and
<br />continue until the bufferzone period expires. Monitor a minimum of 8 times during the
<br />buffer zone period, including these periods:
<br />— 1 hour before sunset,
<br />— during the night
<br />— 1 hour after sunrise, and
<br />— during daylight hours.
<br />Implement the emergency response plan immediately if a handier monitoring experiences
<br />sensory irritation.
<br />Response Information For Neighbors
<br />NOTE: Response Information for Neighbors is ONLY required if the Emergency
<br />Preparedness and Response Measures are triggered AND directions from the
<br />Fumigant Site Monitoring section are not followed.
<br />The certified applicator supervising the application must ensure that residences and
<br />businesses thattngger the requirement have been provided the response information at least
<br />1 week before the application starts..The information provided may include application dates
<br />that range for no more than 4 weeks. If the appllcatlon does not occur when specified, the
<br />information must be delivered again.
<br />Information that must be included:
<br />• The location of the application block,
<br />• Fumigant(s) applied including the active ingredient, name of the"fumigant product(s), and
<br />the EPA Registration number.
<br />• Contact information for the applicator and property owner,
<br />• Time period in which the application is planned to take place (must not range more than 4
<br />weeks).
<br />• Early signs and symptoms of exposure to the fumigant(s) applied, what to do, and who to
<br />call If you believe you are being exposed (911 In most cases):
<br />• How to find additional information aboutfumlgants:
<br />The method used to share the response information for neighbors can be accomplished
<br />through mailings, door hangers, or other methods that will effectively inform the residences
<br />and businesses within the required distance from the edge of the bufferzone.
<br />NOTICE.TO STATE AND TRIBAL LEAD AGENCIES
<br />If your state and/or tribal lead agency requires notice, information must be provided to the
<br />appropriate state or tribal lead agency prior to the application, Please refer to www.epa.
<br />goy/funiluantstatenotfce for a list of states and tribal lead agencies thatrequire notice and
<br />information on how to.submit the Information.
<br />The information that must be provided to state and tribal lead agencies includes the following:
<br />• Location of the application blocks,
<br />• Fumigant(s) applied including EPA registration number,
<br />• Applicator and property owner contact Information, and
<br />• Time period that fumigation may occur.
<br />EMERGENCY RESPONSE PLAN
<br />The certified applicator must include In the FMP a written emergency response planthat
<br />identifies:
<br />• evacuation routes,
<br />• locations of telephones,
<br />RMI
<br />6/1212015 10:2556 AM
<br />*i
<br />
|